Bug 428468
IBM 8832 megaide in RAID mode causes data corruption
[?]
New
Simple Search
Advanced Search
My Links
Browse
Requests
Reports
Current State
Search
Tabular reports
Graphical reports
Duplicates
Other Reports
User Changes
Plotly Reports
Bug Status
Bug Severity
Non-Defaults
|
Product Dashboard
Help
Page Help!
Bug Writing Guidelines
What's new
Browser Support Policy
5.0.4.rh83 Release notes
FAQ
Guides index
User guide
Web Services
Contact
Legal
This site requires JavaScript to be enabled to function correctly, please enable it.
lspci output - Fedora 8 rescue environment
lspci-f8-recovery-unmodified.txt (text/plain), 16.34 KB, created by
Ian McLeod
on 2008-01-13 21:33:53 UTC
(
hide
)
Description:
lspci output - Fedora 8 rescue environment
Filename:
MIME Type:
Creator:
Ian McLeod
Created:
2008-01-13 21:33:53 UTC
Size:
16.34 KB
patch
obsolete
>00:00.0 Host bridge: Broadcom CMIC-LE Host Bridge (GC-LE chipset) (rev 33) > Control: I/O- Mem- BusMaster- SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- > Status: Cap- 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- >00: 66 11 14 00 00 00 00 00 33 00 00 06 10 00 80 00 >10: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >20: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >30: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >40: 00 00 00 00 00 00 00 00 02 c3 00 47 00 00 b6 23 >50: 00 00 00 82 00 00 00 00 00 00 00 00 00 00 00 00 >60: 00 00 00 10 00 00 00 10 66 66 00 00 00 00 00 00 >70: 42 aa 00 aa 80 0f ff 0f 01 10 00 00 00 02 00 88 >80: 00 10 10 20 20 30 30 40 00 00 00 00 00 00 00 00 >90: 0f 00 77 20 00 0f 00 0f 00 04 00 25 10 00 6a 00 >a0: 20 00 01 00 1a 1a 1a 1a 00 08 04 01 0f fb 00 00 >b0: 00 00 00 00 00 00 00 00 74 7d 00 07 a1 d9 0f 43 >c0: c0 0f ff 0f c0 0f bf 0f 01 00 00 00 00 44 28 20 >d0: 00 00 ff 22 01 00 00 00 08 04 08 08 00 00 32 01 >e0: 0c 00 00 00 00 00 00 00 69 bf cd f0 0b 58 3b 44 >f0: 0f fb 00 00 69 bf cd f0 00 00 00 00 c0 00 00 00 > >00:00.1 Host bridge: Broadcom CMIC-LE Host Bridge (GC-LE chipset) > Control: I/O- Mem- BusMaster- SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- > Status: Cap- 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- >00: 66 11 14 00 00 00 00 00 00 00 00 06 10 00 80 00 >10: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >20: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >30: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >40: 00 00 00 00 01 02 00 00 00 00 00 07 00 00 00 00 >50: 00 00 04 00 00 00 00 00 00 00 00 00 00 00 00 00 >60: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >70: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >80: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >90: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >a0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >b0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >c0: a0 0f bf 0f a0 0f 9f 0f 01 00 00 1f f3 40 7c 01 >d0: 00 23 ff 22 01 00 00 00 12 10 10 84 04 04 00 00 >e0: 00 00 00 00 a2 04 00 00 b2 10 81 00 00 00 01 00 >f0: 1f 2e 10 00 00 00 00 00 00 00 01 00 00 00 00 00 > >00:00.2 Host bridge: Broadcom CMIC-LE Host Bridge (GC-LE chipset) > Control: I/O- Mem- BusMaster- SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- > Status: Cap- 66MHz- UDF- FastB2B- ParErr- DEVSEL=fast >TAbort- <TAbort- <MAbort- >SERR- <PERR- >00: 66 11 14 00 00 00 00 00 00 00 00 06 10 00 80 00 >10: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >20: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >30: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >40: 00 00 00 00 03 04 00 00 00 00 00 03 00 00 00 00 >50: 00 00 00 00 00 00 00 00 28 6c 93 00 00 00 00 00 >60: 88 aa 88 22 aa 7f bb bb 04 01 00 00 00 0d 0f 00 >70: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >80: 10 40 00 00 50 80 00 00 00 00 00 00 00 00 00 00 >90: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >a0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >b0: 90 01 01 00 d0 01 02 00 00 00 00 00 00 00 00 00 >c0: a0 0f 9f 0f a0 0f 9f 0f 00 00 00 00 f3 40 7c 01 >d0: 00 23 ff ff 01 00 00 00 12 10 10 84 04 04 00 00 >e0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >f0: 1f 3e 80 09 10 32 00 00 01 00 00 00 00 20 0a 08 > >00:01.0 VGA compatible controller: ATI Technologies Inc Rage XL (rev 27) (prog-if 00 [VGA]) > Subsystem: IBM Unknown device 0240 > Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr- Stepping+ SERR- FastB2B- > Status: Cap+ 66MHz- UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort- >SERR- <PERR- > Latency: 64 (2000ns min), Cache Line Size: 32 bytes > Interrupt: pin A routed to IRQ 9 > Region 0: Memory at fd000000 (32-bit, non-prefetchable) [size=16M] > Region 1: I/O ports at 2200 [size=256] > Region 2: Memory at febff000 (32-bit, non-prefetchable) [size=4K] > [virtual] Expansion ROM at f8800000 [disabled] [size=128K] > Capabilities: [5c] Power Management version 2 > Flags: PMEClk- DSI- D1+ D2+ AuxCurrent=0mA PME(D0-,D1-,D2-,D3hot-,D3cold-) > Status: D0 PME-Enable- DSel=0 DScale=0 PME- >00: 02 10 52 47 87 00 90 02 27 00 00 03 08 40 00 00 >10: 00 00 00 fd 01 22 00 00 00 f0 bf fe 00 00 00 00 >20: 00 00 00 00 00 00 00 00 00 00 00 00 14 10 40 02 >30: 00 00 00 00 5c 00 00 00 00 00 00 00 09 01 08 00 >40: 0c 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >50: 02 5c 10 00 01 00 00 ff 00 00 00 00 01 00 02 06 >60: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >70: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >80: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >90: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >a0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >b0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >c0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >d0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >e0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >f0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 > >00:0f.0 Host bridge: Broadcom CSB6 South Bridge (rev b0) > Subsystem: Broadcom Unknown device 0201 > Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr+ Stepping- SERR+ FastB2B- > Status: Cap- 66MHz- UDF- FastB2B- ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort+ >SERR- <PERR- > Latency: 64 >00: 66 11 03 02 47 01 00 22 b0 00 00 06 00 40 80 00 >10: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >20: 00 00 00 00 00 00 00 00 00 00 00 00 66 11 01 02 >30: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >40: 00 3e 3e 20 03 ef 00 00 07 00 00 00 02 04 50 24 >50: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >60: 00 00 00 00 ff c3 d3 5d 00 00 00 60 00 00 00 02 >70: 0f 00 00 00 00 00 00 00 80 00 00 00 00 00 00 00 >80: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >90: 41 04 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >a0: 93 0e 00 00 08 01 80 0f ff 0f 04 10 01 aa 00 00 >b0: 00 fc 1c 00 00 00 00 00 00 00 00 00 00 00 00 00 >c0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >d0: 00 00 03 00 00 00 00 00 00 00 00 00 00 00 00 00 >e0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >f0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 > >00:0f.1 RAID bus controller: Broadcom CSB6 RAID/IDE Controller (rev b0) (prog-if 8f) > Subsystem: IBM Unknown device 0213 > Control: I/O+ Mem- BusMaster+ SpecCycle- MemWINV+ VGASnoop- ParErr+ Stepping- SERR+ FastB2B- > Status: Cap+ 66MHz- UDF- FastB2B- ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort- >SERR- <PERR- > Latency: 64, Cache Line Size: 32 bytes > Interrupt: pin B routed to IRQ 11 > Region 0: I/O ports at 0730 [size=8] > Region 1: I/O ports at 0724 [size=4] > Region 2: I/O ports at 0728 [size=8] > Region 3: I/O ports at 0720 [size=4] > Region 4: I/O ports at 0710 [size=16] > Capabilities: [b0] Power Management version 2 > Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0-,D1-,D2-,D3hot-,D3cold-) > Status: D0 PME-Enable- DSel=0 DScale=0 PME- >00: 66 11 13 02 55 01 10 02 b0 8f 04 01 08 40 80 00 >10: 31 07 00 00 25 07 00 00 29 07 00 00 21 07 00 00 >20: 11 07 00 00 00 00 00 00 00 00 00 00 14 10 13 02 >30: 00 00 00 00 b0 00 00 00 00 00 00 00 0b 02 00 00 >40: 99 20 99 20 ff 20 ff 20 00 00 04 04 00 00 00 00 >50: 00 00 00 00 05 00 05 55 0f 04 03 00 00 00 00 00 >60: 00 00 00 00 01 08 00 00 00 00 00 00 00 00 00 00 >70: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >80: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >90: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >a0: 00 00 00 00 00 00 00 6c 00 00 00 00 00 00 00 00 >b0: 01 00 02 00 00 00 00 00 00 00 00 00 00 00 00 00 >c0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >d0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >e0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >f0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 > >00:0f.2 USB Controller: Broadcom CSB6 OHCI USB Controller (rev 05) (prog-if 10 [OHCI]) > Subsystem: Broadcom Unknown device 0220 > Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV+ VGASnoop- ParErr+ Stepping- SERR+ FastB2B- > Status: Cap- 66MHz- UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort- >SERR- <PERR- > Latency: 64 (20000ns max), Cache Line Size: 32 bytes > Interrupt: pin A routed to IRQ 7 > Region 0: Memory at febfe000 (32-bit, non-prefetchable) [size=4K] >00: 66 11 21 02 57 01 80 02 05 10 03 0c 08 40 80 00 >10: 00 e0 bf fe 00 00 00 00 00 00 00 00 00 00 00 00 >20: 00 00 00 00 00 00 00 00 00 00 00 00 66 11 20 02 >30: 00 00 00 00 00 00 00 00 00 00 00 00 07 01 00 50 >40: 00 00 0f 00 00 00 00 00 00 00 00 00 00 00 00 00 >50: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >60: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >70: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >80: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >90: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >a0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >b0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >c0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >d0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >e0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >f0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 > >00:0f.3 ISA bridge: Broadcom GCLE-2 Host Bridge > Subsystem: Broadcom Unknown device 0230 > Control: I/O- Mem- BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr+ Stepping- SERR+ FastB2B- > Status: Cap- 66MHz- UDF- FastB2B- ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort- >SERR- <PERR- > Latency: 0 >00: 66 11 27 02 44 01 00 02 00 00 01 06 00 00 80 00 >10: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >20: 00 00 00 00 00 00 00 00 00 00 00 00 66 11 30 02 >30: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >40: 04 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >50: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >60: ff ff 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >70: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >80: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >90: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >a0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >b0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >c0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >d0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >e0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >f0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 > >00:10.0 Host bridge: Broadcom CIOB-E I/O Bridge with Gigabit Ethernet (rev 12) > Control: I/O- Mem+ BusMaster- SpecCycle- MemWINV- VGASnoop- ParErr+ Stepping- SERR+ FastB2B- > Status: Cap+ 66MHz+ UDF- FastB2B- ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort+ >SERR- <PERR- > Capabilities: [60] PCI-X non-bridge device > Command: DPERE- ERO- RBC=512 OST=8 > Status: Dev=00:00.0 64bit+ 133MHz+ SCD+ USC- DC=bridge DMMRBC=512 DMOST=8 DMCRS=8 RSCEM- 266MHz- 533MHz- >00: 66 11 10 01 42 01 30 22 12 00 00 06 00 40 80 00 >10: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >20: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >30: 00 00 00 00 60 00 00 00 00 00 00 00 00 00 00 00 >40: 00 00 00 00 02 02 fc 00 00 ff 00 00 00 00 00 00 >50: e1 d2 76 07 08 10 38 0c 00 00 00 00 00 00 00 00 >60: 07 00 40 00 00 00 17 02 00 00 00 00 00 00 00 00 >70: 00 aa 00 00 80 0f ff 0f 20 00 00 18 1f 00 00 81 >80: 08 01 00 00 01 00 00 00 01 40 00 18 00 00 00 00 >90: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >a0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >b0: 00 00 00 00 00 80 40 00 00 00 00 00 00 00 00 00 >c0: a0 0f 9f 0f a0 0f 9f 0f 00 00 00 00 00 00 00 00 >d0: 00 23 fc 22 00 00 00 00 00 00 00 00 00 00 00 00 >e0: 00 00 04 00 00 00 00 00 00 00 00 00 ca 00 00 00 >f0: f3 40 7c 01 88 87 8a 1f 17 37 78 0a 00 00 00 11 > >00:10.2 Host bridge: Broadcom CIOB-E I/O Bridge with Gigabit Ethernet (rev 12) > Control: I/O- Mem+ BusMaster- SpecCycle- MemWINV- VGASnoop- ParErr+ Stepping- SERR+ FastB2B- > Status: Cap+ 66MHz+ UDF- FastB2B- ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort+ >SERR- <PERR- > Capabilities: [60] PCI-X non-bridge device > Command: DPERE- ERO- RBC=512 OST=8 > Status: Dev=00:00.0 64bit+ 133MHz+ SCD+ USC+ DC=bridge DMMRBC=512 DMOST=8 DMCRS=8 RSCEM- 266MHz- 533MHz- >00: 66 11 10 01 42 01 30 22 12 00 00 06 00 40 80 00 >10: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >20: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >30: 00 00 00 00 60 00 00 00 00 00 00 00 00 00 00 00 >40: 00 00 00 00 01 01 fc 00 00 ff 00 00 00 00 00 20 >50: e1 d2 76 07 08 10 38 0c 00 00 00 00 00 00 00 00 >60: 07 00 40 00 00 00 1f 02 00 00 00 00 00 00 00 00 >70: 00 aa 00 00 80 0f ff 0f 00 00 00 18 1f 00 00 81 >80: 08 01 00 00 01 00 00 18 00 00 00 18 00 00 00 00 >90: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >a0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >b0: 00 00 00 00 02 00 00 40 00 00 00 00 00 00 00 00 >c0: a0 0f bf 0f a0 0f 9f 0f 01 00 04 00 01 00 00 00 >d0: 00 23 fc 22 00 00 00 00 00 00 00 00 00 00 00 00 >e0: 00 00 00 18 00 00 00 00 00 00 00 00 ca 00 00 00 >f0: f3 40 7c 01 88 87 8a 1f 17 37 78 0a 00 00 00 11 > >01:00.0 Ethernet controller: Broadcom Corporation NetXtreme BCM5704S Gigabit Ethernet (rev 02) > Subsystem: IBM Unknown device 029c > Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr+ Stepping- SERR+ FastB2B- > Status: Cap+ 66MHz+ UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort- >SERR- <PERR- > Latency: 64 (16000ns min) > Interrupt: pin A routed to IRQ 16 > Region 0: Memory at fbff0000 (64-bit, non-prefetchable) [size=64K] > Region 2: Memory at fbfe0000 (64-bit, non-prefetchable) [size=64K] > Capabilities: [40] PCI-X non-bridge device > Command: DPERE- ERO- RBC=2048 OST=1 > Status: Dev=01:00.0 64bit+ 133MHz+ SCD- USC- DC=simple DMMRBC=2048 DMOST=1 DMCRS=16 RSCEM- 266MHz- 533MHz- > Capabilities: [48] Power Management version 2 > Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0-,D1-,D2-,D3hot+,D3cold+) > Status: D0 PME-Enable+ DSel=0 DScale=1 PME- > Capabilities: [50] Vital Product Data > Capabilities: [58] Message Signalled Interrupts: Mask- 64bit+ Queue=0/3 Enable- > Address: 290051db00011c00 Data: 2000 >00: e4 14 a8 16 46 01 b0 02 02 00 00 02 00 40 80 00 >10: 04 00 ff fb 00 00 00 00 04 00 fe fb 00 00 00 00 >20: 00 00 00 00 00 00 00 00 00 00 00 00 14 10 9c 02 >30: 00 00 00 00 40 00 00 00 00 00 00 00 0a 01 40 00 >40: 07 48 08 00 00 01 43 04 01 50 02 c0 00 21 00 00 >50: 03 58 80 00 04 00 90 40 05 00 86 00 00 1c 01 00 >60: db 51 00 29 00 20 00 00 98 02 02 20 00 40 9f 76 >70: ea 30 00 00 a7 00 00 80 10 04 00 00 00 00 00 00 >80: 09 00 00 00 03 87 ab 9a 34 00 13 04 82 f0 28 02 >90: 09 93 00 01 01 00 00 00 00 00 00 00 bc 00 00 00 >a0: 00 00 00 00 f4 03 00 00 00 00 00 00 74 00 00 00 >b0: 00 00 00 00 00 00 00 af 00 00 00 00 00 00 00 00 >c0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >d0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >e0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >f0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 > >01:00.1 Ethernet controller: Broadcom Corporation NetXtreme BCM5704S Gigabit Ethernet (rev 02) > Subsystem: IBM Unknown device 029c > Control: I/O- Mem+ BusMaster+ SpecCycle- MemWINV- VGASnoop- ParErr+ Stepping- SERR+ FastB2B- > Status: Cap+ 66MHz+ UDF- FastB2B+ ParErr- DEVSEL=medium >TAbort- <TAbort- <MAbort- >SERR- <PERR- > Latency: 64 (16000ns min), Cache Line Size: 32 bytes > Interrupt: pin B routed to IRQ 17 > Region 0: Memory at fbfd0000 (64-bit, non-prefetchable) [size=64K] > Region 2: Memory at fbfc0000 (64-bit, non-prefetchable) [size=64K] > Capabilities: [40] PCI-X non-bridge device > Command: DPERE- ERO+ RBC=512 OST=1 > Status: Dev=01:00.1 64bit+ 133MHz+ SCD- USC- DC=simple DMMRBC=2048 DMOST=1 DMCRS=16 RSCEM- 266MHz- 533MHz- > Capabilities: [48] Power Management version 2 > Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA PME(D0-,D1-,D2-,D3hot+,D3cold+) > Status: D0 PME-Enable- DSel=0 DScale=1 PME- > Capabilities: [50] Vital Product Data > Capabilities: [58] Message Signalled Interrupts: Mask- 64bit+ Queue=0/3 Enable- > Address: 009000004000100c Data: 0000 >00: e4 14 a8 16 46 01 b0 02 02 00 00 02 08 40 80 00 >10: 04 00 fd fb 00 00 00 00 04 00 fc fb 00 00 00 00 >20: 00 00 00 00 00 00 00 00 00 00 00 00 14 10 9c 02 >30: 00 00 00 00 40 00 00 00 00 00 00 00 0b 02 40 00 >40: 07 48 02 00 01 01 43 04 01 50 02 c0 00 20 00 64 >50: 03 58 60 00 c8 00 08 42 05 00 86 00 0c 10 00 40 >60: 00 00 90 00 00 00 00 00 9a 02 02 20 00 40 9f 76 >70: 8a 32 00 00 a7 00 00 00 10 04 00 00 00 00 00 00 >80: 09 00 00 00 cc b7 06 be 34 00 00 00 82 f0 60 02 >90: 01 03 00 01 00 00 00 00 00 00 00 00 00 00 00 00 >a0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >b0: 00 00 00 00 00 00 00 00 04 00 00 00 00 00 00 00 >c0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >d0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >e0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >f0: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >
You cannot view the attachment while viewing its details because your browser does not support IFRAMEs.
View the attachment on a separate page
.
View Attachment As Raw
Actions:
View
Attachments on
bug 428468
:
291417
|
291464
|
291516
|
291517
| 291518