Login
[x]
Log in using an account from:
Fedora Account System
Red Hat Associate
Red Hat Customer
Or login using a Red Hat Bugzilla account
Forgot Password
Login:
Hide Forgot
Create an Account
Red Hat Bugzilla – Attachment 605543 Details for
Bug 849433
Discharge estimate is wrong when using APC ups
[?]
New
Simple Search
Advanced Search
My Links
Browse
Requests
Reports
Current State
Search
Tabular reports
Graphical reports
Duplicates
Other Reports
User Changes
Plotly Reports
Bug Status
Bug Severity
Non-Defaults
|
Product Dashboard
Help
Page Help!
Bug Writing Guidelines
What's new
Browser Support Policy
5.0.4.rh83 Release notes
FAQ
Guides index
User guide
Web Services
Contact
Legal
This site requires JavaScript to be enabled to function correctly, please enable it.
Discharge Comparison
discharge_comparison.txt (text/plain), 6.49 KB, created by
Douglas Furlong
on 2012-08-19 21:15:43 UTC
(
hide
)
Description:
Discharge Comparison
Filename:
MIME Type:
Creator:
Douglas Furlong
Created:
2012-08-19 21:15:43 UTC
Size:
6.49 KB
patch
obsolete
>[root@akasa ~]# upower -d; apcaccess >Device: /org/freedesktop/UPower/devices/ups_hiddev0 > native-path: /sys/devices/pci0000:00/0000:00:1d.2/usb7/7-1/7-1:1.0/usb/hiddev0 > vendor: American Power Conversion > model: Back-UPS BR 800 > serial: 5Q1018T24867 > power supply: yes > updated: Sun Aug 19 16:00:41 2012 (10 seconds ago) > has history: yes > has statistics: yes > ups > present: yes > state: discharging > time to empty: 14.1 minutes > percentage: 48% > >Daemon: > daemon-version: 0.9.17 > can-suspend: yes > can-hibernate yes > on-battery: yes > on-low-battery: no > lid-is-closed: no > lid-is-present: no > is-docked: no >APC : 001,046,1165 >DATE : 2012-08-19 16:00:48 +0100 >HOSTNAME : akasa.local >VERSION : 3.14.10 (13 September 2011) redhat >UPSNAME : akasa.local >CABLE : USB Cable >DRIVER : USB UPS Driver >UPSMODE : Stand Alone >STARTTIME: 2012-08-19 13:52:34 +0100 >MODEL : Back-UPS BR 800 >STATUS : ONBATT >LINEV : 000.0 Volts >LOADPCT : 30.0 Percent Load Capacity >BCHARGE : 031.0 Percent >TIMELEFT : 8.4 Minutes >MBATTCHG : 0 Percent >MINTIMEL : 0 Minutes >MAXTIME : 0 Seconds >OUTPUTV : 230.0 Volts >SENSE : Medium >DWAKE : 000 Seconds >DSHUTD : 000 Seconds >LOTRANS : 194.0 Volts >HITRANS : 264.0 Volts >RETPCT : 000.0 Percent >ITEMP : 29.2 C Internal >ALARMDEL : 30 seconds >BATTV : 22.8 Volts >LINEFREQ : 50.0 Hz >LASTXFER : Low line voltage >NUMXFERS : 2 >XONBATT : 2012-08-19 15:55:03 +0100 >TONBATT : 348 seconds >CUMONBATT: 527 seconds >XOFFBATT : 2012-08-19 14:41:58 +0100 >SELFTEST : NO >STESTI : None >STATFLAG : 0x07060010 Status Flag >MANDATE : 2011-02-17 >SERIALNO : 5Q1018T24867 >BATTDATE : 2011-02-17 >NOMOUTV : 230 Volts >NOMINV : 230 Volts >NOMBATTV : 24.0 Volts >NOMPOWER : 540 Watts >FIRMWARE : 9.o5 .I USB FW:o5 >END APC : 2012-08-19 16:00:51 +0100 >[root@akasa ~]# apcaccess | grep BCHARGE;upower -d | grep percentage;apcaccess | grep TIMELEFT;upower -d | grep "time to empty" >BCHARGE : 030.0 Percent > percentage: 48% >TIMELEFT : 8.1 Minutes > time to empty: 14.1 minutes > > >[root@akasa ~]# upower -d; apcaccess ;apcaccess | grep BCHARGE;upower -d | grep percentage;apcaccess | grep TIMELEFT;upower -d | grep "time to empty" >Device: /org/freedesktop/UPower/devices/ups_hiddev0 > native-path: /sys/devices/pci0000:00/0000:00:1d.2/usb7/7-1/7-1:1.0/usb/hiddev0 > vendor: American Power Conversion > model: Back-UPS BR 800 > serial: 5Q1018T24867 > power supply: yes > updated: Sun Aug 19 16:01:41 2012 (21 seconds ago) > has history: yes > has statistics: yes > ups > present: yes > state: discharging > time to empty: 13.2 minutes > percentage: 46% > >Daemon: > daemon-version: 0.9.17 > can-suspend: yes > can-hibernate yes > on-battery: yes > on-low-battery: no > lid-is-closed: no > lid-is-present: no > is-docked: no >APC : 001,046,1165 >DATE : 2012-08-19 16:01:58 +0100 >HOSTNAME : akasa.local >VERSION : 3.14.10 (13 September 2011) redhat >UPSNAME : akasa.local >CABLE : USB Cable >DRIVER : USB UPS Driver >UPSMODE : Stand Alone >STARTTIME: 2012-08-19 13:52:34 +0100 >MODEL : Back-UPS BR 800 >STATUS : ONBATT >LINEV : 000.0 Volts >LOADPCT : 30.0 Percent Load Capacity >BCHARGE : 022.0 Percent >TIMELEFT : 6.6 Minutes >MBATTCHG : 0 Percent >MINTIMEL : 0 Minutes >MAXTIME : 0 Seconds >OUTPUTV : 230.0 Volts >SENSE : Medium >DWAKE : 000 Seconds >DSHUTD : 000 Seconds >LOTRANS : 194.0 Volts >HITRANS : 264.0 Volts >RETPCT : 000.0 Percent >ITEMP : 29.2 C Internal >ALARMDEL : 30 seconds >BATTV : 22.4 Volts >LINEFREQ : 50.0 Hz >LASTXFER : Low line voltage >NUMXFERS : 2 >XONBATT : 2012-08-19 15:55:03 +0100 >TONBATT : 419 seconds >CUMONBATT: 598 seconds >XOFFBATT : 2012-08-19 14:41:58 +0100 >SELFTEST : NO >STESTI : None >STATFLAG : 0x07060010 Status Flag >MANDATE : 2011-02-17 >SERIALNO : 5Q1018T24867 >BATTDATE : 2011-02-17 >NOMOUTV : 230 Volts >NOMINV : 230 Volts >NOMBATTV : 24.0 Volts >NOMPOWER : 540 Watts >FIRMWARE : 9.o5 .I USB FW:o5 >END APC : 2012-08-19 16:02:02 +0100 >BCHARGE : 022.0 Percent > percentage: 46% >TIMELEFT : 6.6 Minutes > time to empty: 13.2 minutes > >[root@akasa ~]# upower -d; apcaccess ;apcaccess | grep BCHARGE;upower -d | grep percentage;apcaccess | grep TIMELEFT;upower -d | grep "time to empty" >Device: /org/freedesktop/UPower/devices/ups_hiddev0 > native-path: /sys/devices/pci0000:00/0000:00:1d.2/usb7/7-1/7-1:1.0/usb/hiddev0 > vendor: American Power Conversion > model: Back-UPS BR 800 > serial: 5Q1018T24867 > power supply: yes > updated: Sun Aug 19 16:03:11 2012 (7 seconds ago) > has history: yes > has statistics: yes > ups > present: yes > state: discharging > time to empty: 14.4 minutes > percentage: 45% > >Daemon: > daemon-version: 0.9.17 > can-suspend: yes > can-hibernate yes > on-battery: yes > on-low-battery: no > lid-is-closed: no > lid-is-present: no > is-docked: no >APC : 001,046,1165 >DATE : 2012-08-19 16:03:13 +0100 >HOSTNAME : akasa.local >VERSION : 3.14.10 (13 September 2011) redhat >UPSNAME : akasa.local >CABLE : USB Cable >DRIVER : USB UPS Driver >UPSMODE : Stand Alone >STARTTIME: 2012-08-19 13:52:34 +0100 >MODEL : Back-UPS BR 800 >STATUS : ONBATT >LINEV : 000.0 Volts >LOADPCT : 30.0 Percent Load Capacity >BCHARGE : 015.0 Percent >TIMELEFT : 4.1 Minutes >MBATTCHG : 0 Percent >MINTIMEL : 0 Minutes >MAXTIME : 0 Seconds >OUTPUTV : 230.0 Volts >SENSE : Medium >DWAKE : 000 Seconds >DSHUTD : 000 Seconds >LOTRANS : 194.0 Volts >HITRANS : 264.0 Volts >RETPCT : 000.0 Percent >ITEMP : 29.2 C Internal >ALARMDEL : 30 seconds >BATTV : 22.1 Volts >LINEFREQ : 50.0 Hz >LASTXFER : Low line voltage >NUMXFERS : 2 >XONBATT : 2012-08-19 15:55:03 +0100 >TONBATT : 495 seconds >CUMONBATT: 674 seconds >XOFFBATT : 2012-08-19 14:41:58 +0100 >SELFTEST : NO >STESTI : None >STATFLAG : 0x07060010 Status Flag >MANDATE : 2011-02-17 >SERIALNO : 5Q1018T24867 >BATTDATE : 2011-02-17 >NOMOUTV : 230 Volts >NOMINV : 230 Volts >NOMBATTV : 24.0 Volts >NOMPOWER : 540 Watts >FIRMWARE : 9.o5 .I USB FW:o5 >END APC : 2012-08-19 16:03:18 +0100 >BCHARGE : 015.0 Percent > percentage: 45% >TIMELEFT : 4.1 Minutes > time to empty: 14.4 minutes >
You cannot view the attachment while viewing its details because your browser does not support IFRAMEs.
View the attachment on a separate page
.
View Attachment As Raw
Actions:
View
Attachments on
bug 849433
:
605484
| 605543 |
605544