Back to bug 1394495
| Who | When | What | Removed | Added |
|---|---|---|---|---|
| Kefu Chai | 2016-11-14 06:46:35 UTC | Link ID | Ceph Project Bug Tracker 17725 | |
| Samuel Just | 2016-11-14 16:45:49 UTC | Assignee | sjust | kchai |
| Samuel Just | 2016-11-14 16:46:31 UTC | Status | NEW | ASSIGNED |
| CC | sjust | |||
| Harish NV Rao | 2016-11-18 07:44:26 UTC | CC | hnallurv | |
| Blocks | 1383917 | |||
| Doc Text | Cause: Consequence: Removes the mon successfully but the error message is still displayed. Workaround (if any): Result: | |||
| Doc Type | If docs needed, set a value | Known Issue | ||
| Bara Ancincova | 2016-11-21 13:58:38 UTC | Docs Contact | bancinco | |
| Doc Text | Cause: Consequence: Removes the mon successfully but the error message is still displayed. Workaround (if any): Result: | .An error is returned when removing a Ceph Monitor When removing a Ceph Monitor by using the `ceph mon remove` command, the Monitor is successfully removed but an error message similar to the following one is returned: ---- Error EINVAL: removing mon.magna072 at 10.8.128.72:6789/0, there will be 3 monitors ---- This error message can be safely ignored. | ||
| Flags | needinfo?(kchai) | |||
| Kefu Chai | 2016-11-22 04:41:59 UTC | Flags | needinfo?(kchai) | |
| Bara Ancincova | 2016-11-22 12:37:58 UTC | Doc Text | .An error is returned when removing a Ceph Monitor When removing a Ceph Monitor by using the `ceph mon remove` command, the Monitor is successfully removed but an error message similar to the following one is returned: ---- Error EINVAL: removing mon.magna072 at 10.8.128.72:6789/0, there will be 3 monitors ---- This error message can be safely ignored. | .An error is returned when removing a Ceph Monitor When removing a Ceph Monitor by using the `ceph mon remove` command, the Monitor is successfully removed but an error message similar to the following is returned: ---- Error EINVAL: removing mon.magna072 at 10.8.128.72:6789/0, there will be 3 monitors ---- You can safely ignore this error message. |
| Samuel Just | 2017-01-04 21:33:58 UTC | Status | ASSIGNED | POST |
| Ken Dreyer (Red Hat) | 2017-01-09 17:36:02 UTC | CC | kdreyer | |
| Flags | needinfo?(kchai) | |||
| Uday Boppana | 2017-01-14 01:00:35 UTC | Priority | unspecified | medium |
| CC | uboppana | |||
| Harish NV Rao | 2017-01-17 11:09:49 UTC | QA Contact | ceph-qe-bugs | shmohan |
| Josh Durgin | 2017-01-18 09:01:30 UTC | CC | jdurgin | |
| Kefu Chai | 2017-01-18 10:55:17 UTC | Flags | needinfo?(kchai) | |
| Ken Dreyer (Red Hat) | 2017-01-20 23:42:47 UTC | Status | POST | MODIFIED |
| Fixed In Version | RHEL: ceph-10.2.5-7.el7cp Ubuntu: ceph_10.2.5-3redhat1xenial | |||
| errata-xmlrpc | 2017-01-20 23:51:21 UTC | Status | MODIFIED | ON_QA |
| shylesh | 2017-02-04 07:28:28 UTC | Flags | needinfo?(kchai) | |
| Kefu Chai | 2017-02-06 02:53:45 UTC | Flags | needinfo?(kchai) | |
| shylesh | 2017-02-06 06:45:16 UTC | Status | ON_QA | VERIFIED |
| Bara Ancincova | 2017-02-13 12:25:39 UTC | Blocks | 1412948 | |
| Doc Text | .An error is returned when removing a Ceph Monitor When removing a Ceph Monitor by using the `ceph mon remove` command, the Monitor is successfully removed but an error message similar to the following is returned: ---- Error EINVAL: removing mon.magna072 at 10.8.128.72:6789/0, there will be 3 monitors ---- You can safely ignore this error message. | .An error is no longer returned when removing a Ceph Monitor When removing a Ceph Monitor by using the `ceph mon remove` command, the Monitor was successfully removed but an error message similar to the following was returned: ---- Error EINVAL: removing mon.magna072 at 10.8.128.72:6789/0, there will be 3 monitors ---- The underlying source code has been fixed, and the error is no longer returned when removing Ceph Monitors. | ||
| Doc Type | Known Issue | Bug Fix | ||
| Flags | needinfo?(kchai) | |||
| Kefu Chai | 2017-02-21 06:45:47 UTC | Flags | needinfo?(kchai) | |
| Bara Ancincova | 2017-02-24 08:51:23 UTC | Doc Text | .An error is no longer returned when removing a Ceph Monitor When removing a Ceph Monitor by using the `ceph mon remove` command, the Monitor was successfully removed but an error message similar to the following was returned: ---- Error EINVAL: removing mon.magna072 at 10.8.128.72:6789/0, there will be 3 monitors ---- The underlying source code has been fixed, and the error is no longer returned when removing Ceph Monitors. | .Removing a Ceph Monitor no longer returns an error When removing a Ceph Monitor by using the `ceph mon remove` command, the Monitor was successfully removed, but an error message similar to the following was returned: ---- Error EINVAL: removing mon.magna072 at 10.8.128.72:6789/0, there will be 3 monitors ---- The underlying source code has been fixed, and the error is no longer returned when removing Ceph Monitors. |
| errata-xmlrpc | 2017-03-13 11:58:13 UTC | Status | VERIFIED | RELEASE_PENDING |
| errata-xmlrpc | 2017-03-14 15:46:47 UTC | Status | RELEASE_PENDING | CLOSED |
| Resolution | --- | ERRATA | ||
| Last Closed | 2017-03-14 11:46:47 UTC | |||
| Drew Harris | 2017-07-30 15:15:43 UTC | Sub Component | RADOS | |
| Component | Ceph | RADOS | ||
| Veera Raghava Reddy | 2022-02-21 18:17:33 UTC | Severity | unspecified | medium |
Back to bug 1394495