Back to bug 1952060
| Who | When | What | Removed | Added |
|---|---|---|---|---|
| yogananth subramanian | 2021-04-21 12:50:55 UTC | Summary | Support OVS auto balance parameters though TripleO | [RFE] Support OVS auto balance parameters though TripleO |
| Brandon Perkins | 2021-04-21 13:35:38 UTC | CC | bperkins | |
| Haresh Khandelwal | 2021-04-21 14:36:30 UTC | Priority | unspecified | medium |
| Status | NEW | ASSIGNED | ||
| Keywords | FutureFeature, Triaged | |||
| CC | hakhande | |||
| Assignee | rhos-maint | ysubrama | ||
| Doc Type | If docs needed, set a value | Technology Preview | ||
| Severity | unspecified | medium | ||
| yogananth subramanian | 2021-05-24 18:49:28 UTC | Component | puppet-tripleo | tripleo-ansible |
| Assignee | ysubrama | rhos-maint | ||
| QA Contact | drosenfe | jhakimra | ||
| Karrar Fida | 2021-06-10 19:40:43 UTC | CC | kfida | |
| Target Milestone | --- | z1 | ||
| RHEL Program Management | 2021-06-10 19:40:52 UTC | Target Release | --- | 16.2 (Train on RHEL 8.4) |
| Sanjay Upadhyay | 2021-06-24 11:38:38 UTC | CC | supadhya | |
| Lon Hohberger | 2021-07-09 16:28:14 UTC | Assignee | rhos-maint | rhos-maint |
| Karrar Fida | 2021-08-09 20:35:33 UTC | Target Milestone | z1 | z2 |
| James Smith | 2021-09-09 04:29:26 UTC | CC | jamsmith, rhos-maint | |
| Flags | needinfo?(rhos-maint) | |||
| Haresh Khandelwal | 2021-09-13 17:21:31 UTC | Doc Type | Technology Preview | Enhancement |
| Ofer Blaut | 2021-09-19 11:13:30 UTC | CC | oblaut | |
| Ofer Blaut | 2021-09-19 11:14:46 UTC | Blocks | 1880239 | |
| Karrar Fida | 2021-09-23 11:47:25 UTC | Flags | needinfo?(ysubrama) | |
| Franck Baudin | 2021-09-28 08:08:25 UTC | CC | fbaudin | |
| Keywords | TechPreview | |||
| Franck Baudin | 2021-09-28 09:03:34 UTC | CC | fbaudin | |
| yogananth subramanian | 2021-10-18 05:58:59 UTC | Status | ASSIGNED | POST |
| yogananth subramanian | 2021-11-09 07:34:31 UTC | Link ID | OpenStack gerrit 797481 | |
| yogananth subramanian | 2021-11-09 07:35:48 UTC | Link ID | OpenStack gerrit 798817 OpenStack gerrit 797480 OpenStack gerrit 798801 | |
| yogananth subramanian | 2021-11-09 09:48:56 UTC | Link ID | OpenStack gerrit 798801 | |
| yogananth subramanian | 2021-11-09 09:48:59 UTC | Link ID | OpenStack gerrit 798817 | |
| yogananth subramanian | 2021-11-09 09:52:17 UTC | Link ID | OpenStack gerrit 798801 OpenStack gerrit 798817 | |
| Red Hat One Jira (issues.redhat.com) | 2021-11-11 13:23:42 UTC | CC | spower | |
| Link ID | Red Hat Issue Tracker OSP-3217 | |||
| Thierry Vignaud | 2022-02-04 16:13:55 UTC | Flags | needinfo?(rhos-maint) | |
| Red Hat One Jira (issues.redhat.com) | 2022-02-04 16:21:03 UTC | Link ID | Red Hat Issue Tracker NFV-2097 | |
| Haresh Khandelwal | 2022-02-07 16:43:19 UTC | Status | POST | ON_QA |
| Lon Hohberger | 2022-02-14 19:19:23 UTC | Fixed In Version | tripleo-ansible-0.8.1-2.20220112214927.5e744eb.el8ost, openstack-tripleo-heat-templates-11.6.1-2.20220116004909.64b2e88.el8ost.noarch.rpm | |
| OSP Team | 2022-02-15 07:01:40 UTC | Fixed In Version | tripleo-ansible-0.8.1-2.20220112214927.5e744eb.el8ost, openstack-tripleo-heat-templates-11.6.1-2.20220116004909.64b2e88.el8ost.noarch.rpm | tripleo-ansible-0.8.1-2.20220112214927.5e744eb.el8ost openstack-tripleo-heat-templates-11.6.1-2.20220116004909.64b2e88.el8ost |
| Miguel Angel Nieto | 2022-02-25 14:41:40 UTC | CC | mnietoji | |
| Status | ON_QA | VERIFIED | ||
| James Smith | 2022-03-07 23:06:04 UTC | Flags | needinfo?(ysubrama) needinfo?(hakhande) needinfo?(mgeary) | |
| Doc Text | With this update, you can use RHOSP director to set the following OVS auto balance parameters. * OvsPmdAutoLb + Enable/disable the OVS DPDK PMD Auto Load Balance feature. Values: true or false. OVS DPDK uses the default value of false. * OvsPmdLoadThreshold + Set Minimum PMD thread load threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum PMD thread load threshold(% of used cycles) of any non-isolated PMD threads when a PMD Auto Load Balance may be triggered. * OvsPmdImprovementThreshold + Set PMD load variance improvement threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum evaluated % improvement in load distribution across the non-isolated PMD threads that will allow a PMD Auto Load Balance to occur. * OvsPmdRebalInterval + Set PMD auto load balancing interval for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 20,000 to specify the minimum time (in minutes) between 2 consecutive PMD Auto Load Balancing iterations. | |||
| CC | mgeary | |||
| Haresh Khandelwal | 2022-03-08 07:49:44 UTC | Flags | needinfo?(hakhande) | needinfo?(mgeary) |
| James Smith | 2022-03-10 17:43:31 UTC | Flags | needinfo?(mgeary) | |
| Doc Type | Enhancement | Technology Preview | ||
| James Smith | 2022-03-22 02:07:27 UTC | Doc Text | With this update, you can use RHOSP director to set the following OVS auto balance parameters. * OvsPmdAutoLb + Enable/disable the OVS DPDK PMD Auto Load Balance feature. Values: true or false. OVS DPDK uses the default value of false. * OvsPmdLoadThreshold + Set Minimum PMD thread load threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum PMD thread load threshold(% of used cycles) of any non-isolated PMD threads when a PMD Auto Load Balance may be triggered. * OvsPmdImprovementThreshold + Set PMD load variance improvement threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum evaluated % improvement in load distribution across the non-isolated PMD threads that will allow a PMD Auto Load Balance to occur. * OvsPmdRebalInterval + Set PMD auto load balancing interval for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 20,000 to specify the minimum time (in minutes) between 2 consecutive PMD Auto Load Balancing iterations. | With this technology preview update, you can use RHOSP director to set the following OVS auto balance parameters. * OvsPmdAutoLb + Enable/disable the OVS DPDK PMD Auto Load Balance feature. Values: true or false. OVS DPDK uses the default value of false. * OvsPmdLoadThreshold + Set Minimum PMD thread load threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum PMD thread load threshold(% of used cycles) of any non-isolated PMD threads when a PMD Auto Load Balance may be triggered. * OvsPmdImprovementThreshold + Set PMD load variance improvement threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum evaluated % improvement in load distribution across the non-isolated PMD threads that will allow a PMD Auto Load Balance to occur. * OvsPmdRebalInterval + Set PMD auto load balancing interval for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 20,000 to specify the minimum time (in minutes) between 2 consecutive PMD Auto Load Balancing iterations. |
| James Smith | 2022-03-22 22:20:39 UTC | Doc Text | With this technology preview update, you can use RHOSP director to set the following OVS auto balance parameters. * OvsPmdAutoLb + Enable/disable the OVS DPDK PMD Auto Load Balance feature. Values: true or false. OVS DPDK uses the default value of false. * OvsPmdLoadThreshold + Set Minimum PMD thread load threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum PMD thread load threshold(% of used cycles) of any non-isolated PMD threads when a PMD Auto Load Balance may be triggered. * OvsPmdImprovementThreshold + Set PMD load variance improvement threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum evaluated % improvement in load distribution across the non-isolated PMD threads that will allow a PMD Auto Load Balance to occur. * OvsPmdRebalInterval + Set PMD auto load balancing interval for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 20,000 to specify the minimum time (in minutes) between 2 consecutive PMD Auto Load Balancing iterations. | With this technology preview update, you can use RHOSP director to set the following OVS auto balance parameters. * OvsPmdAutoLb + Enable/disable the OVS DPDK PMD Auto Load Balance feature. Values: true or false. OVS DPDK uses the default value of false. * OvsPmdLoadThreshold + Set the minimum PMD thread load threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum PMD thread load threshold (% of used cycles) of any non-isolated PMD threads when a PMD Auto Load Balance might be triggered. * OvsPmdImprovementThreshold + Set PMD load variance improvement threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum evaluated % improvement in load distribution across the non-isolated PMD threads that will allow a PMD Auto Load Balance to occur. * OvsPmdRebalInterval + Set PMD auto load balancing interval for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 20,000 to specify the minimum time (in minutes) between 2 consecutive PMD Auto Load Balancing iterations. |
| James Smith | 2022-03-22 22:24:44 UTC | Doc Text | With this technology preview update, you can use RHOSP director to set the following OVS auto balance parameters. * OvsPmdAutoLb + Enable/disable the OVS DPDK PMD Auto Load Balance feature. Values: true or false. OVS DPDK uses the default value of false. * OvsPmdLoadThreshold + Set the minimum PMD thread load threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum PMD thread load threshold (% of used cycles) of any non-isolated PMD threads when a PMD Auto Load Balance might be triggered. * OvsPmdImprovementThreshold + Set PMD load variance improvement threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum evaluated % improvement in load distribution across the non-isolated PMD threads that will allow a PMD Auto Load Balance to occur. * OvsPmdRebalInterval + Set PMD auto load balancing interval for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 20,000 to specify the minimum time (in minutes) between 2 consecutive PMD Auto Load Balancing iterations. | With this technology preview update, you can use RHOSP director to set the following OVS auto balance parameters. * OvsPmdAutoLb + Enable/disable the OVS DPDK PMD Auto Load Balance feature. Values: true or false. OVS DPDK uses the default value of false. * OvsPmdLoadThreshold + Set the minimum PMD thread load threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum PMD thread load threshold (percentage of used cycles) of any non-isolated PMD threads when a PMD Auto Load Balance might be triggered. * OvsPmdImprovementThreshold + Set PMD load variance improvement threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum evaluated percentage improvement in load distribution across the non-isolated PMD threads that allows a PMD Auto Load Balance to occur. * OvsPmdRebalInterval + Set PMD auto load balancing interval for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 20,000 to specify the minimum time (in minutes) between 2 consecutive PMD Auto Load Balancing iterations. |
| errata-xmlrpc | 2022-03-23 18:19:46 UTC | Status | VERIFIED | RELEASE_PENDING |
| errata-xmlrpc | 2022-03-23 22:10:08 UTC | Resolution | --- | ERRATA |
| Status | RELEASE_PENDING | CLOSED | ||
| Last Closed | 2022-03-23 22:10:08 UTC | |||
| errata-xmlrpc | 2022-03-23 22:10:32 UTC | Link ID | Red Hat Product Errata RHBA-2022:1001 | |
| mgeary | 2022-04-05 14:21:19 UTC | Doc Text | With this technology preview update, you can use RHOSP director to set the following OVS auto balance parameters. * OvsPmdAutoLb + Enable/disable the OVS DPDK PMD Auto Load Balance feature. Values: true or false. OVS DPDK uses the default value of false. * OvsPmdLoadThreshold + Set the minimum PMD thread load threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum PMD thread load threshold (percentage of used cycles) of any non-isolated PMD threads when a PMD Auto Load Balance might be triggered. * OvsPmdImprovementThreshold + Set PMD load variance improvement threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum evaluated percentage improvement in load distribution across the non-isolated PMD threads that allows a PMD Auto Load Balance to occur. * OvsPmdRebalInterval + Set PMD auto load balancing interval for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 20,000 to specify the minimum time (in minutes) between 2 consecutive PMD Auto Load Balancing iterations. | With this technology preview update, you can use RHOSP director to set the following OVS PMD auto load balance parameters. * OvsPmdAutoLb + Enable/disable the OVS DPDK PMD Auto Load Balance feature. Values: true or false. OVS DPDK uses the default value of false. * OvsPmdLoadThreshold + Set the minimum PMD thread load threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum PMD thread load threshold (percentage of used cycles) of any non-isolated PMD threads when a PMD Auto Load Balance might be triggered. * OvsPmdImprovementThreshold + Set PMD load variance improvement threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum evaluated percentage improvement in load distribution across the non-isolated PMD threads that allows a PMD Auto Load Balance to occur. * OvsPmdRebalInterval + Set PMD auto load balancing interval for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 20,000 to specify the minimum time (in minutes) between 2 consecutive PMD Auto Load Balancing iterations. |
| mgeary | 2022-04-07 13:11:12 UTC | Doc Text | With this technology preview update, you can use RHOSP director to set the following OVS PMD auto load balance parameters. * OvsPmdAutoLb + Enable/disable the OVS DPDK PMD Auto Load Balance feature. Values: true or false. OVS DPDK uses the default value of false. * OvsPmdLoadThreshold + Set the minimum PMD thread load threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum PMD thread load threshold (percentage of used cycles) of any non-isolated PMD threads when a PMD Auto Load Balance might be triggered. * OvsPmdImprovementThreshold + Set PMD load variance improvement threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum evaluated percentage improvement in load distribution across the non-isolated PMD threads that allows a PMD Auto Load Balance to occur. * OvsPmdRebalInterval + Set PMD auto load balancing interval for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 20,000 to specify the minimum time (in minutes) between 2 consecutive PMD Auto Load Balancing iterations. | With this technology preview update, you can configure OVS PMD auto load balance with the following parameters: * OvsPmdAutoLb Enable/disable the OVS DPDK PMD Auto Load Balance feature. Values: true or false. OVS DPDK uses the default value of false. * OvsPmdLoadThreshold Set the minimum PMD thread load threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum PMD thread load threshold (percentage of used cycles) of any non-isolated PMD threads when a PMD Auto Load Balance might be triggered. * OvsPmdImprovementThreshold Set PMD load variance improvement threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum evaluated percentage improvement in load distribution across the non-isolated PMD threads that allows a PMD Auto Load Balance to occur. * OvsPmdRebalInterval Set PMD auto load balancing interval for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 20,000 to specify the minimum time (in minutes) between 2 consecutive PMD Auto Load Balancing iterations. |
| mgeary | 2022-04-08 11:21:21 UTC | Doc Text | With this technology preview update, you can configure OVS PMD auto load balance with the following parameters: * OvsPmdAutoLb Enable/disable the OVS DPDK PMD Auto Load Balance feature. Values: true or false. OVS DPDK uses the default value of false. * OvsPmdLoadThreshold Set the minimum PMD thread load threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum PMD thread load threshold (percentage of used cycles) of any non-isolated PMD threads when a PMD Auto Load Balance might be triggered. * OvsPmdImprovementThreshold Set PMD load variance improvement threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum evaluated percentage improvement in load distribution across the non-isolated PMD threads that allows a PMD Auto Load Balance to occur. * OvsPmdRebalInterval Set PMD auto load balancing interval for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 20,000 to specify the minimum time (in minutes) between 2 consecutive PMD Auto Load Balancing iterations. | With this technology preview update, you can set the following parameters to configure OVS PMD auto load balance: * OvsPmdAutoLb Enable/disable the OVS DPDK PMD Auto Load Balance feature. Values: true or false. OVS DPDK uses the default value of false. * OvsPmdLoadThreshold Set the minimum PMD thread load threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum PMD thread load threshold (percentage of used cycles) of any non-isolated PMD threads when a PMD Auto Load Balance might be triggered. * OvsPmdImprovementThreshold Set PMD load variance improvement threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum evaluated percentage improvement in load distribution across the non-isolated PMD threads that allows a PMD Auto Load Balance to occur. * OvsPmdRebalInterval Set PMD auto load balancing interval for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 20,000 to specify the minimum time (in minutes) between 2 consecutive PMD Auto Load Balancing iterations. |
| mgeary | 2022-04-08 11:25:53 UTC | Doc Text | With this technology preview update, you can set the following parameters to configure OVS PMD auto load balance: * OvsPmdAutoLb Enable/disable the OVS DPDK PMD Auto Load Balance feature. Values: true or false. OVS DPDK uses the default value of false. * OvsPmdLoadThreshold Set the minimum PMD thread load threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum PMD thread load threshold (percentage of used cycles) of any non-isolated PMD threads when a PMD Auto Load Balance might be triggered. * OvsPmdImprovementThreshold Set PMD load variance improvement threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum evaluated percentage improvement in load distribution across the non-isolated PMD threads that allows a PMD Auto Load Balance to occur. * OvsPmdRebalInterval Set PMD auto load balancing interval for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 20,000 to specify the minimum time (in minutes) between 2 consecutive PMD Auto Load Balancing iterations. | With this technology preview update, you can set the following parameters to configure OVS PMD auto load balance: * `OvsPmdAutoLb` Enable/disable the OVS DPDK PMD Auto Load Balance feature. Values: true or false. OVS DPDK uses the default value of false. * `OvsPmdLoadThreshold` Set the minimum PMD thread load threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum PMD thread load threshold (percentage of used cycles) of any non-isolated PMD threads when a PMD Auto Load Balance might be triggered. * `OvsPmdImprovementThreshold` Set PMD load variance improvement threshold for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 100 to specify the minimum evaluated percentage improvement in load distribution across the non-isolated PMD threads that allows a PMD Auto Load Balance to occur. * `OvsPmdRebalInterval` Set PMD auto load balancing interval for OVS DPDK PMD Auto Load Balance feature. Set a value from 0 to 20,000 to specify the minimum time (in minutes) between 2 consecutive PMD Auto Load Balancing iterations. |
| mgeary | 2022-05-17 07:23:07 UTC | Flags | needinfo?(mgeary) needinfo?(mgeary) needinfo?(mgeary) | |
| mgeary | 2022-05-17 07:24:24 UTC | Flags | needinfo?(rhos-maint) needinfo?(ysubrama) needinfo?(rhos-maint) needinfo?(ysubrama) |
Back to bug 1952060