Back to bug 2090712
| Who | When | What | Removed | Added |
|---|---|---|---|---|
| Red Hat Bugzilla | 2022-05-26 12:21:00 UTC | Pool ID | sst_virtualization_networking_rhel_9 | |
| Yanhui Ma | 2022-05-26 12:23:20 UTC | CC | coli | |
| Yanhui Ma | 2022-05-26 12:24:59 UTC | CC | juzhang | |
| Red Hat One Jira (issues.redhat.com) | 2022-05-26 12:49:00 UTC | Link ID | Red Hat Issue Tracker RHELPLAN-123470 | |
| CongLi | 2022-05-27 00:29:04 UTC | CC | coli, juzhang | |
| Laurent Vivier | 2022-05-31 07:25:44 UTC | Pool ID | sst_virtualization_networking_rhel_9 | sst_virtualization_windows_rhel_9 |
| Keywords | Triaged | |||
| Yanhui Ma | 2022-05-31 11:12:02 UTC | Flags | needinfo?(lvivier) | |
| Laurent Vivier | 2022-05-31 15:12:35 UTC | Flags | needinfo?(lvivier) | needinfo?(yvugenfi) |
| CC | yvugenfi | |||
| Yvugenfi | 2022-06-01 10:27:13 UTC | CC | ybendito | |
| Flags | needinfo?(ybendito) | |||
| Yanghang Liu | 2022-06-02 10:26:35 UTC | CC | yanghliu | |
| Yvugenfi | 2022-06-23 09:37:22 UTC | Flags | needinfo?(yvugenfi) | |
| Jiri Herrmann | 2022-09-30 10:24:40 UTC | Assignee | virt-maint | ybendito |
| Flags | needinfo?(ybendito) | |||
| Docs Contact | davozeni | |||
| CC | jherrman | |||
| Doc Type | If docs needed, set a value | Known Issue | ||
| Gabi Fialová | 2022-10-24 13:33:48 UTC | Flags | needinfo?(ybendito) | |
| CC | gfialova | |||
| Gabi Fialová | 2022-10-31 14:07:41 UTC | CC | gfialova | |
| Daniel Vozenilek | 2022-11-02 08:59:20 UTC | Doc Text | .Certain network adapters do not work correctly on Windows VMs after live migration The following network adapters do not work correctly on Windows virtual machines (VMs) after live migration: * Marvell FastLinQ QL41000 * Solarflare SFC9220 * Broadcom BCM57810 * Intel 82599ES * Mellanox MT2892 Currently, the listed network adapters do not work correctly when hot unplugged from a Windows VM, which is needed for successful live migration. | |
| Flags | needinfo?(yvugenfi) | |||
| Yvugenfi | 2022-11-03 09:17:33 UTC | Flags | needinfo?(yvugenfi) | |
| Daniel Vozenilek | 2022-11-09 14:09:35 UTC | Doc Text | .Certain network adapters do not work correctly on Windows VMs after live migration The following network adapters do not work correctly on Windows virtual machines (VMs) after live migration: * Marvell FastLinQ QL41000 * Solarflare SFC9220 * Broadcom BCM57810 * Intel 82599ES * Mellanox MT2892 Currently, the listed network adapters do not work correctly when hot unplugged from a Windows VM, which is needed for successful live migration. | .Broadcom network adapters do not work correctly on Windows VMs after a live migration Network adapters from the Broadcom family of devices (Broadcom, Qlogic, Marvell) currently do not work correctly on Windows virtual machines (VMs) after a live migration. There is a bug that prevents the adapter from plugging correctly in a Windows VM. Since the hot-unplug feature is required for implementing SR-IOV failover during a live migration, the network adapter will not work correctly on the migrated Windows VM. |
| Flags | needinfo?(yvugenfi) | |||
| Yvugenfi | 2022-11-09 14:45:04 UTC | Flags | needinfo?(yvugenfi) | |
| Daniel Vozenilek | 2022-11-10 13:43:20 UTC | Flags | needinfo?(yvugenfi) | |
| Yvugenfi | 2022-11-10 14:48:28 UTC | Flags | needinfo?(yvugenfi) | |
| Daniel Vozenilek | 2022-11-11 17:15:19 UTC | Doc Text | .Broadcom network adapters do not work correctly on Windows VMs after a live migration Network adapters from the Broadcom family of devices (Broadcom, Qlogic, Marvell) currently do not work correctly on Windows virtual machines (VMs) after a live migration. There is a bug that prevents the adapter from plugging correctly in a Windows VM. Since the hot-unplug feature is required for implementing SR-IOV failover during a live migration, the network adapter will not work correctly on the migrated Windows VM. | .Broadcom network adapters work incorrectly on Windows VMs after a live migration Currently, network adapters from the Broadcom family of devices, such as Broadcom, Qlogic, or Marvell, cannot be hot-unplugged during live migration of Windows virtual machines (VMs). As a consequence, the adapters work incorrectly after the migration is complete. This problem affects only those adapters that are attached to Windows VMs using Single-root I/O virtualization (SR-IOV). |
| Yanhui Ma | 2023-03-24 04:36:07 UTC | Severity | high | medium |
| Priority | high | medium | ||
| Yanhui Ma | 2023-06-05 02:26:43 UTC | Flags | needinfo?(ybendito) | |
| Yvugenfi | 2023-06-28 08:24:27 UTC | Flags | needinfo?(ybendito) needinfo?(ybendito) | |
| Yvugenfi | 2023-06-28 08:24:58 UTC | Status | NEW | CLOSED |
| Resolution | --- | MIGRATED | ||
| Last Closed | 2023-06-28 08:24:58 UTC | |||
| Yanhui Ma | 2023-07-24 05:36:55 UTC | CC | qizhu | |
| Yanhui Ma | 2023-07-27 07:23:11 UTC | QA Contact | yama | virt-bugs |
| Assignee | ybendito | mdean | ||
| Docs Contact | davozeni | |||
| Component | qemu-kvm | virtio-win | ||
| Sub Component | Networking | virtio-win-prewhql | ||
| Qianqian Zhu | 2023-07-31 02:26:14 UTC | Assignee | mdean | ybendito |
| Keywords | MigratedToJIRA | |||
| Red Hat One Jira (issues.redhat.com) | 2023-07-31 02:27:45 UTC | Link ID | Red Hat Issue Tracker RHEL-910 |
Back to bug 2090712