Back to bug 2124309
| Who | When | What | Removed | Added |
|---|---|---|---|---|
| Red Hat One Jira (issues.redhat.com) | 2022-09-05 15:43:11 UTC | Link ID | Red Hat Issue Tracker OSP-18550 | |
| Rabi Mishra | 2022-09-06 04:11:40 UTC | CC | ramishra | |
| Flags | needinfo?(astupnik) | |||
| Alex Stupnikov | 2022-09-06 07:51:11 UTC | Flags | needinfo?(astupnik) | |
| Luca Miccini | 2022-09-06 11:10:26 UTC | CC | lmiccini | |
| Luca Miccini | 2022-09-07 05:30:00 UTC | Keywords | Triaged | |
| Priority | unspecified | low | ||
| Luca Miccini | 2022-09-07 06:32:59 UTC | Link ID | OpenStack gerrit 856233 | |
| Luca Miccini | 2022-09-07 06:34:13 UTC | CC | jjoyce, jschluet, slinaber, tvignaud | |
| Component | openstack-tripleo-heat-templates | puppet-pacemaker | ||
| QA Contact | jhakimra | nlevinki | ||
| Luca Miccini | 2022-12-05 16:06:33 UTC | Status | NEW | MODIFIED |
| Fixed In Version | puppet-pacemaker-1.5.1-1.20221120001158.31e7487.el9ost | |||
| Luca Miccini | 2022-12-05 16:07:49 UTC | Target Release | --- | 17.1 |
| Target Milestone | --- | ga | ||
| errata-xmlrpc | 2022-12-14 10:10:53 UTC | Status | MODIFIED | ON_QA |
| Luca Miccini | 2023-05-02 14:32:18 UTC | Status | ON_QA | VERIFIED |
| Andy Stillman | 2023-05-31 21:04:30 UTC | CC | dabarzil | |
| QA Contact | nlevinki | dabarzil | ||
| CC | rhos-maint | |||
| Flags | needinfo?(rhos-maint) | |||
| Luca Miccini | 2023-06-01 05:01:37 UTC | Flags | needinfo?(rhos-maint) | |
| Doc Text | Feature: Operators can now enable the run_arping feature for pacemaker managed virtual ips, so that the cluster checks for duplicate ips preemptively. This can be accomplished by setting: ExtraConfig: pacemaker::resource::ip::run_arping: true Reason: To prevent duplicate ips in the network fabric. Result: Pacemaker resource will be configured like the following: Resource: ip-172.17.3.115 (class=ocf provider=heartbeat type=IPaddr2) Attributes: ip-172.17.3.115-instance_attributes cidr_netmask=32 ip=172.17.3.115 run_arping=true If a duplicate is found the following error will be logged in /var/log/pacemaker/pacemaker.log: Sep 07 05:54:54 IPaddr2(ip-172.17.3.115)[209771]: ERROR: IPv4 address collision 172.17.3.115 [DAD] Sep 07 05:54:54 IPaddr2(ip-172.17.3.115)[209771]: ERROR: Failed to add 172.17.3.115 | |||
| Doc Type | If docs needed, set a value | Enhancement | ||
| Joanne O'Flynn | 2023-06-08 08:15:37 UTC | Flags | needinfo?(lmiccini) | |
| CC | joflynn | |||
| Luca Miccini | 2023-06-08 10:36:10 UTC | Flags | needinfo?(lmiccini) | |
| Joanne O'Flynn | 2023-06-08 11:46:23 UTC | Doc Text | Feature: Operators can now enable the run_arping feature for pacemaker managed virtual ips, so that the cluster checks for duplicate ips preemptively. This can be accomplished by setting: ExtraConfig: pacemaker::resource::ip::run_arping: true Reason: To prevent duplicate ips in the network fabric. Result: Pacemaker resource will be configured like the following: Resource: ip-172.17.3.115 (class=ocf provider=heartbeat type=IPaddr2) Attributes: ip-172.17.3.115-instance_attributes cidr_netmask=32 ip=172.17.3.115 run_arping=true If a duplicate is found the following error will be logged in /var/log/pacemaker/pacemaker.log: Sep 07 05:54:54 IPaddr2(ip-172.17.3.115)[209771]: ERROR: IPv4 address collision 172.17.3.115 [DAD] Sep 07 05:54:54 IPaddr2(ip-172.17.3.115)[209771]: ERROR: Failed to add 172.17.3.115 | With this enhancement, operators can enable the run_arping feature for Pacemaker-managed virtual IPs (VIPs), so that the cluster preemptively checks for duplicate IPs. To do this, you must add the following configuration to the environment file: ExtraConfig: pacemaker::resource::ip::run_arping: true If a duplicate is found, the following error is logged in the /var/log/pacemaker/pacemaker.log log file: Sep 07 05:54:54 IPaddr2(ip-172.17.3.115)[209771]: ERROR: IPv4 address collision 172.17.3.115 [DAD] Sep 07 05:54:54 IPaddr2(ip-172.17.3.115)[209771]: ERROR: Failed to add 172.17.3.115 |
| Jenny-Anne Lynch | 2023-08-10 12:54:38 UTC | Doc Text | With this enhancement, operators can enable the run_arping feature for Pacemaker-managed virtual IPs (VIPs), so that the cluster preemptively checks for duplicate IPs. To do this, you must add the following configuration to the environment file: ExtraConfig: pacemaker::resource::ip::run_arping: true If a duplicate is found, the following error is logged in the /var/log/pacemaker/pacemaker.log log file: Sep 07 05:54:54 IPaddr2(ip-172.17.3.115)[209771]: ERROR: IPv4 address collision 172.17.3.115 [DAD] Sep 07 05:54:54 IPaddr2(ip-172.17.3.115)[209771]: ERROR: Failed to add 172.17.3.115 | With this enhancement, operators can enable the run_arping feature for Pacemaker-managed virtual IPs (VIPs), so that the cluster preemptively checks for duplicate IPs. + To do this, you must add the following configuration to the environment file: + ---- ExtraConfig: pacemaker::resource::ip::run_arping: true ---- + If a duplicate is found, the following error is logged in the `/var/log/pacemaker/pacemaker.log` file: + ---- Sep 07 05:54:54 IPaddr2(ip-172.17.3.115)[209771]: ERROR: IPv4 address collision 172.17.3.115 [DAD] Sep 07 05:54:54 IPaddr2(ip-172.17.3.115)[209771]: ERROR: Failed to add 172.17.3.115 ---- |
| CC | jelynch | |||
| errata-xmlrpc | 2023-08-16 00:03:34 UTC | Status | VERIFIED | RELEASE_PENDING |
| errata-xmlrpc | 2023-08-16 01:12:07 UTC | Status | RELEASE_PENDING | CLOSED |
| Resolution | --- | ERRATA | ||
| Last Closed | 2023-08-16 01:12:07 UTC | |||
| errata-xmlrpc | 2023-08-16 01:12:31 UTC | Link ID | Red Hat Product Errata RHEA-2023:4577 |