Description Matt Domsch 2000-07-12 14:54:44 UTC
Dell changes the PCI device ID of the 7890 or 7899 controller when it's 
subsumed by the on-board RAID controller.  Kudzu should ignore such a 
device when found.

--- pcitable.orig	Tue Jul 11 03:46:54 2000
+++ pcitable	Tue Jul 11 03:47:28 2000
@@ -2002,6 +2002,7 @@
 0x9005	0x00c0	"aic7xxx"	"Adaptec|7899A"
 0x9005	0x00c1	"aic7xxx"	"Adaptec|7899B"
 0x9005	0x00c3	"aic7xxx"	"Adaptec|7899D"
+0x9005	0x00c5	"ignore"	"Adaptec|RAID subsystem HBA"
 0x9005	0x00cf	"aic7xxx"	"Adaptec|7899P"
 0x907f	0x2015	"unknown"	"Atronics|IDE-2015PL"
 0x9412	0x6565	"ignore"	"Holtek|6565"

Comment 1 Bill Nottingham 2000-07-12 15:56:21 UTC
Committed to CVS, will be in kudzu-0.50-1.

Comment 2 Matt Domsch 2000-07-21 19:00:17 UTC
Missing from kudzu-0.52-3 on Winston Beta 4.

Comment 3 Bill Nottingham 2000-07-21 20:40:01 UTC
Ugh. Will be fixed in beta 5. Really.

Comment 4 Matt Domsch 2000-07-27 21:34:07 UTC
Correct in beta 5.