Bug 1109723
Summary: | [Nagios] Cluster auto-config service is warning with "(null)" status information when glusterd is down on some nodes in the cluster | ||
---|---|---|---|
Product: | [Red Hat Storage] Red Hat Gluster Storage | Reporter: | Shruti Sampat <ssampat> |
Component: | gluster-nagios-addons | Assignee: | Ramesh N <rnachimu> |
Status: | CLOSED ERRATA | QA Contact: | Shruti Sampat <ssampat> |
Severity: | high | Docs Contact: | |
Priority: | unspecified | ||
Version: | rhgs-3.0 | CC: | asrivast, bkunal, dpati, esammons, kmayilsa, psriniva, rhsc-qe-bugs, rnachimu, sharne, vumrao |
Target Milestone: | --- | Keywords: | ZStream |
Target Release: | RHGS 3.0.3 | ||
Hardware: | Unspecified | ||
OS: | Unspecified | ||
Whiteboard: | |||
Fixed In Version: | nagios-server-addons-0.1.7-1.el6rhs | Doc Type: | Bug Fix |
Doc Text: |
Previously, the Auto-config service would not work if the glusterd service was offline in any of the nodes in the Red Hat Storage trusted storage pool. With this fix, the Auto-config service works even if the glusterd service is down in some of the nodes in the trusted storage pool provided that the glusterd service is running in the node which is used as sync host in the auto-config service.
|
Story Points: | --- |
Clone Of: | Environment: | ||
Last Closed: | 2015-01-15 13:48:14 UTC | Type: | Bug |
Regression: | --- | Mount Type: | --- |
Documentation: | --- | CRM: | |
Verified Versions: | Category: | --- | |
oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
Cloudforms Team: | --- | Target Upstream Version: | |
Embargoed: | |||
Bug Depends On: | |||
Bug Blocks: | 1087818 |
Description
Shruti Sampat
2014-06-16 08:55:07 UTC
Similar behavior was seen when some nodes in the cluster were powered off. See BZ #1109025. Fixed in Patch : http://review.gluster.org/#/c/8074/ Downstream patch https://code.engineering.redhat.com/gerrit/#/c/27038/ Review and signoff the edited doc text. Doc text looks good to me. Verified as fixed in nagios-server-addons-0.1.8-1.el6rhs.noarch When glusterd is down on some of the nodes in the cluster, the cluster auto-config service remains OK and does run successfully to sync the cluster configurations. If glusterd is down on the node that is used to sync the cluster configurations via the discovery script, then trying to run the auto-config service will cause it to be in CRITICAL state with the following in the status information - Failed to execute NRPE command 'discover_volume_list' in host <hostname> This is expected as the discovery script fails to run the required commands owing to glusterd being down. Hi Ramesh, Can you please review the edited doc text for technical accuracy and sign off? Doc text looks good to me. Since the problem described in this bug report should be resolved in a recent advisory, it has been closed with a resolution of ERRATA. For information on the advisory, and where to find the updated files, follow the link below. If the solution does not work for you, open a new bug report. https://rhn.redhat.com/errata/RHBA-2015-0039.html |