| Summary: | ovn-controller service does not start automatically at boot | ||
|---|---|---|---|
| Product: | Red Hat Enterprise Linux 7 | Reporter: | Mor <mkalfon> |
| Component: | openvswitch | Assignee: | Mark Michelson <mmichels> |
| Status: | CLOSED CURRENTRELEASE | QA Contact: | qding |
| Severity: | high | Docs Contact: | |
| Priority: | high | ||
| Version: | 7.3 | CC: | aloughla, atragler, fleitner, qding, wchadwic |
| Target Milestone: | rc | ||
| Target Release: | 7.3 | ||
| Hardware: | x86_64 | ||
| OS: | Linux | ||
| Whiteboard: | |||
| Fixed In Version: | openvswitch-2.6.1-1.git20161206.el7fdb | Doc Type: | If docs needed, set a value |
| Doc Text: | Story Points: | --- | |
| Clone Of: | Environment: | ||
| Last Closed: | 2018-02-16 17:00:43 UTC | Type: | Bug |
| Regression: | --- | Mount Type: | --- |
| Documentation: | --- | CRM: | |
| Verified Versions: | Category: | --- | |
| oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
| Cloudforms Team: | --- | Target Upstream Version: | |
|
Description
Mor
2016-11-21 14:25:07 UTC
Good find, this also applies to the ovn-northd and ovn-controller-vtep services. Patch posted upstream: https://patchwork.ozlabs.org/patch/697445/ Also noticed when testing that ovn-common rpm installation fails if pacemaker has not been installed, posted a patch for that issue as well: https://patchwork.ozlabs.org/patch/697444/ Fix has been applied upstream to master and 2.6 branches. RPMs with fix available here:
http://download-node-02.eng.bos.redhat.com/brewroot/packages/openvswitch/2.6.1/2.git20161206.el7fdb/
Verified with openvswitch-2.6.1-2.git20161206.el7fdb.x86_64 Steps as in Comment #0 Closing resolved bugs. |