Bug 1397888

Summary: false-positive monitoring operation result of fence_ipmilan stonith resource
Product: Red Hat Enterprise Linux 7 Reporter: Marcel Kolaja <mkolaja>
Component: fence-agentsAssignee: Marek Grac <mgrac>
Status: CLOSED ERRATA QA Contact: cluster-qe <cluster-qe>
Severity: unspecified Docs Contact:
Priority: high    
Version: 7.4CC: cfeist, chwood, cluster-maint, jhan, mgrac, mjuricek, pzimek, sbradley
Target Milestone: rcKeywords: EasyFix, ZStream
Target Release: ---   
Hardware: Unspecified   
OS: Unspecified   
Whiteboard:
Fixed In Version: fence-agents-4.0.11-27.el7_2.10 Doc Type: Bug Fix
Doc Text:
Previously, monitor action for fence agents was able to succeed even when the fence device was not available. With this update, monitor action properly detects if fence device is working.
Story Points: ---
Clone Of: 1390915 Environment:
Last Closed: 2016-12-20 17:31:56 UTC Type: ---
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Bug Depends On: 1390915    
Bug Blocks:    

Description Marcel Kolaja 2016-11-23 14:07:38 UTC
This bug has been copied from bug #1390915 and has been proposed
to be backported to 7.2 z-stream (EUS).

Comment 6 errata-xmlrpc 2016-12-20 17:31:56 UTC
Since the problem described in this bug report should be
resolved in a recent advisory, it has been closed with a
resolution of ERRATA.

For information on the advisory, and where to find the updated
files, follow the link below.

If the solution does not work for you, open a new bug report.

https://rhn.redhat.com/errata/RHBA-2016-2971.html