| Summary: | Input method offered by ibus does not move to the second window in ZaphodHeads environment | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Product: | Red Hat Enterprise Linux 6 | Reporter: | ptoshniw | ||||||
| Component: | ibus | Assignee: | fujiwara <tfujiwar> | ||||||
| Status: | CLOSED ERRATA | QA Contact: | QE Internationalization Bugs <qe-i18n-bugs> | ||||||
| Severity: | urgent | Docs Contact: | |||||||
| Priority: | urgent | ||||||||
| Version: | 6.8 | CC: | alanm, cww, eng-i18n-bugs, jraising, lijli, peter.hutterer, qe-i18n-bugs, smaitra, tfujiwar, toneata, vchoudha | ||||||
| Target Milestone: | rc | Keywords: | i18n, Reopened, ZStream | ||||||
| Target Release: | 6.9 | ||||||||
| Hardware: | x86_64 | ||||||||
| OS: | Linux | ||||||||
| Whiteboard: | |||||||||
| Fixed In Version: | ibus-1.3.4-10.el6 | Doc Type: | Bug Fix | ||||||
| Doc Text: |
In this release, IBus supports multiple screens in Zaphod mode.
|
Story Points: | --- | ||||||
| Clone Of: | |||||||||
| : | 1420662 1549171 (view as bug list) | Environment: | |||||||
| Last Closed: | 2018-06-19 05:23:07 UTC | Type: | Bug | ||||||
| Regression: | --- | Mount Type: | --- | ||||||
| Documentation: | --- | CRM: | |||||||
| Verified Versions: | Category: | --- | |||||||
| oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |||||||
| Cloudforms Team: | --- | Target Upstream Version: | |||||||
| Bug Depends On: | |||||||||
| Bug Blocks: | 1374441, 1461138, 1510263, 1549171 | ||||||||
| Attachments: |
|
||||||||
Created attachment 1230691 [details]
ibus-zaphodheads.log attached
Thank you for the testing. Seems opening GdkDisplay for the second screen is no problem but gtk.gdk.Display is failed for the second screen. I may mistake the python format. Let me rewrite the test program with C lang. (In reply to ptoshniw from comment #20) Great. thank you for all of your testings. Now all the debuggings are done at the moment and I understood how ibus can launch the lookup table on the second screen. Let me create a tentative fix for this bug for one week or next year. This patch supports GTK2 applications only. I cannot find the client Display variable in XIM protocol. Red Hat Enterprise Linux 6 transitioned to the Production 3 Phase on May 10, 2017. During the Production 3 Phase, Critical impact Security Advisories (RHSAs) and selected Urgent Priority Bug Fix Advisories (RHBAs) may be released as they become available. The official life cycle policy can be reviewed here: http://redhat.com/rhel/lifecycle This issue does not appear to meet the inclusion criteria for the Production Phase 3 and will be marked as CLOSED/WONTFIX. If this remains a critical requirement, please contact Red Hat Customer Support to request a re-evaluation of the issue, citing a clear business justification. Red Hat Customer Support can be contacted via the Red Hat Customer Portal at the following URL: https://access.redhat.com Could you attach the patch? I think it is good to have more eyes on it. The current patch is: https://github.com/fujiwarat/ibus/commits/1.3.y-rhel6 Since the problem described in this bug report should be resolved in a recent advisory, it has been closed with a resolution of ERRATA. For information on the advisory, and where to find the updated files, follow the link below. If the solution does not work for you, open a new bug report. https://access.redhat.com/errata/RHBA-2018:1919 |
Created attachment 1229753 [details] setup_ibus.xml Description of problem: When you use ibus after pressing <ctrl> + <space> user can use Chinese input on screen1 however when he do it on screen2 <ctrl> + <space> does not bring up there the ibus window and user cannot use Chinese input even the ibus cannot cannot be moved to screen2 from screen1 Version-Release number of selected component (if applicable):h ibus-1.3.4-9.el6.x86_64 How reproducible: Always Executed below commands # ibus-daemon -d –x Create a file under user home directory as # cat /home/user/.i18n LC_CTYPE="zh_CN.UTF-8" GTK_IM_MODULE=ibus QT_IM_MODULE=ibus XMODIFIERS=@im=ibus # gconftool-2 --load setup_ibus.xml [1] Opened a terminal on screen1 hit [ctrl+space] when I type I can see Chinese font and the rectangular window for input. [2] Opened another terminal on screen2 moved the mouse to screen2 and started typing, still see Chinese font but does not see the rectangular window on screen two. it remains on screen 1 itself. Actual results: The rectangular input window remains on the screen 1. Expected results: The rectangular input window should move accordingly on which we are working and entering the chinese characters.. Additional info: It is happening in the zaphod environment.