Bug 1455284
Summary: | virsh nodecpumap shows wrong cpus present output | ||
---|---|---|---|
Product: | [Community] Virtualization Tools | Reporter: | Satheesh Rajendran <sathnaga> |
Component: | libvirt | Assignee: | Libvirt Maintainers <libvirt-maint> |
Status: | CLOSED NEXTRELEASE | QA Contact: | |
Severity: | high | Docs Contact: | |
Priority: | unspecified | ||
Version: | unspecified | CC: | libvirt-maint, pkrempa, rbalakri |
Target Milestone: | --- | ||
Target Release: | --- | ||
Hardware: | ppc64le | ||
OS: | Linux | ||
Whiteboard: | |||
Fixed In Version: | Doc Type: | If docs needed, set a value | |
Doc Text: | Story Points: | --- | |
Clone Of: | Environment: | ||
Last Closed: | 2017-05-30 08:43:53 UTC | Type: | Bug |
Regression: | --- | Mount Type: | --- |
Documentation: | --- | CRM: | |
Verified Versions: | Category: | --- | |
oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
Cloudforms Team: | --- | Target Upstream Version: | |
Embargoed: |
Description
Satheesh Rajendran
2017-05-24 16:16:24 UTC
Fixed upstream: commit 4ae0f65669a6672a408e08698678ed2958a77fde Author: Nitesh Konkar <niteshkonkar.libvirt> Date: Thu May 25 15:47:43 2017 +0530 util: hostcpu: Correctly report total number of vcpus in virHostCPUGetMap Callers expect the return value to be the total number of vcpus in the host (including offline vcpus). The refactor in c67e04e25fa58104e0fae41 broke this assumption by using virHostCPUGetOnlineBitmap which only creates a bitmap long enough to hold the last online vcpu. Report the full number of host vcpus by returning value from virHostCPUGetCount(). |