Bug 1462108
Summary: | 0xc0000001 error when install win2016 guest with gluster backend | ||
---|---|---|---|
Product: | Red Hat Enterprise Linux 7 | Reporter: | Suqin Huang <shuang> |
Component: | qemu-kvm-rhev | Assignee: | Jeff Cody <jcody> |
Status: | CLOSED INSUFFICIENT_DATA | QA Contact: | Longxiang Lyu <lolyu> |
Severity: | high | Docs Contact: | |
Priority: | high | ||
Version: | 7.4 | CC: | aliang, areis, chayang, coli, juzhang, knoel, lolyu, michen, shuang, virt-maint |
Target Milestone: | rc | Keywords: | Regression |
Target Release: | --- | ||
Hardware: | Unspecified | ||
OS: | Unspecified | ||
Whiteboard: | |||
Fixed In Version: | Doc Type: | If docs needed, set a value | |
Doc Text: | Story Points: | --- | |
Clone Of: | Environment: | ||
Last Closed: | 2017-12-11 15:26:29 UTC | Type: | Bug |
Regression: | --- | Mount Type: | --- |
Documentation: | --- | CRM: | |
Verified Versions: | Category: | --- | |
oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
Cloudforms Team: | --- | Target Upstream Version: | |
Embargoed: | |||
Bug Depends On: | |||
Bug Blocks: | 1473046 |
Comment 2
Suqin Huang
2017-06-16 08:20:20 UTC
the env for qemu-kvm-rhev-2.6.0-28.el7_3.2.x86_64 testing is the same as qemu-kvm-rhev-2.9.0-10.el7.x86_64.rpm, I need to double check qemu-kvm-rhev-2.9.0-1.el7.x86_64.rpm, as I test it before, the server is the same, but I'm not sure the client # qemu-img info gluster://bootp-73-199-197.lab.eng.pek2.redhat.com:0/gv0/win2016-64-virtio-scsi.qcow2 [2017-06-20 05:50:52.975478] I [MSGID: 104045] [glfs-master.c:91:notify] 0-gfapi: New graph 68702d64-6c33-3838-6738-2d31362e7268 (0) coming up [2017-06-20 05:50:52.975554] I [MSGID: 114020] [client.c:2356:notify] 0-gv0-client-0: parent translators are ready, attempting connect on transport [2017-06-20 05:50:52.979341] I [MSGID: 114020] [client.c:2356:notify] 0-gv0-client-1: parent translators are ready, attempting connect on transport [2017-06-20 05:50:52.980121] I [rpc-clnt.c:2001:rpc_clnt_reconfig] 0-gv0-client-0: changing port to 49152 (from 0) [2017-06-20 05:50:52.983242] I [rpc-clnt.c:2001:rpc_clnt_reconfig] 0-gv0-client-1: changing port to 49152 (from 0) [2017-06-20 05:50:52.985821] I [MSGID: 114057] [client-handshake.c:1439:select_server_supported_programs] 0-gv0-client-0: Using Program GlusterFS 3.3, Num (1298437), Version (330) [2017-06-20 05:50:52.986350] I [MSGID: 114046] [client-handshake.c:1215:client_setvolume_cbk] 0-gv0-client-0: Connected to gv0-client-0, attached to remote volume '/data/brick1/gv0'. [2017-06-20 05:50:52.986365] I [MSGID: 114047] [client-handshake.c:1226:client_setvolume_cbk] 0-gv0-client-0: Server and Client lk-version numbers are not same, reopening the fds [2017-06-20 05:50:52.986411] I [MSGID: 108005] [afr-common.c:4659:afr_notify] 0-gv0-replicate-0: Subvolume 'gv0-client-0' came back up; going online. [2017-06-20 05:50:52.986937] I [MSGID: 114035] [client-handshake.c:201:client_set_lk_version_cbk] 0-gv0-client-0: Server lk version = 1 [2017-06-20 05:50:52.988417] I [MSGID: 114057] [client-handshake.c:1439:select_server_supported_programs] 0-gv0-client-1: Using Program GlusterFS 3.3, Num (1298437), Version (330) [2017-06-20 05:50:52.989045] I [MSGID: 114046] [client-handshake.c:1215:client_setvolume_cbk] 0-gv0-client-1: Connected to gv0-client-1, attached to remote volume '/data/brick1/gv0'. [2017-06-20 05:50:52.989060] I [MSGID: 114047] [client-handshake.c:1226:client_setvolume_cbk] 0-gv0-client-1: Server and Client lk-version numbers are not same, reopening the fds [2017-06-20 05:50:53.004248] I [MSGID: 114035] [client-handshake.c:201:client_set_lk_version_cbk] 0-gv0-client-1: Server lk version = 1 [2017-06-20 05:50:53.006433] I [MSGID: 104041] [glfs-resolve.c:885:__glfs_active_subvol] 0-gv0: switched to graph 68702d64-6c33-3838-6738-2d31362e7268 (0) [2017-06-20 05:50:53.008280] W [MSGID: 114031] [client-rpc-fops.c:2211:client3_3_seek_cbk] 0-gv0-client-0: remote operation failed [No such device or address] [2017-06-20 05:50:53.014621] I [MSGID: 114021] [client.c:2365:notify] 0-gv0-client-0: current graph is no longer active, destroying rpc_client [2017-06-20 05:50:53.014660] I [MSGID: 114021] [client.c:2365:notify] 0-gv0-client-1: current graph is no longer active, destroying rpc_client [2017-06-20 05:50:53.014667] I [MSGID: 114018] [client.c:2280:client_rpc_notify] 0-gv0-client-0: disconnected from gv0-client-0. Client process will keep trying to connect to glusterd until brick's port is available [2017-06-20 05:50:53.014726] I [MSGID: 114018] [client.c:2280:client_rpc_notify] 0-gv0-client-1: disconnected from gv0-client-1. Client process will keep trying to connect to glusterd until brick's port is available [2017-06-20 05:50:53.014745] E [MSGID: 108006] [afr-common.c:4684:afr_notify] 0-gv0-replicate-0: All subvolumes are down. Going offline until atleast one of them comes back up. [2017-06-20 05:50:53.015548] I [MSGID: 101053] [mem-pool.c:641:mem_pool_destroy] 0-gfapi: size=84 max=1 total=1 [2017-06-20 05:50:53.015642] I [MSGID: 101053] [mem-pool.c:641:mem_pool_destroy] 0-gfapi: size=188 max=2 total=2 [2017-06-20 05:50:53.015956] I [MSGID: 101053] [mem-pool.c:641:mem_pool_destroy] 0-gfapi: size=140 max=2 total=8 [2017-06-20 05:50:53.016002] I [MSGID: 101053] [mem-pool.c:641:mem_pool_destroy] 0-gv0-client-0: size=1316 max=3 total=6 [2017-06-20 05:50:53.016013] I [MSGID: 101053] [mem-pool.c:641:mem_pool_destroy] 0-gv0-client-1: size=1316 max=2 total=8 [2017-06-20 05:50:53.016026] I [MSGID: 101053] [mem-pool.c:641:mem_pool_destroy] 0-gv0-replicate-0: size=11708 max=2 total=8 [2017-06-20 05:50:53.016180] I [MSGID: 101053] [mem-pool.c:641:mem_pool_destroy] 0-gv0-dht: size=1148 max=0 total=0 [2017-06-20 05:50:53.016238] I [MSGID: 101053] [mem-pool.c:641:mem_pool_destroy] 0-gv0-dht: size=3380 max=2 total=7 [2017-06-20 05:50:53.016366] I [MSGID: 101053] [mem-pool.c:641:mem_pool_destroy] 0-gv0-read-ahead: size=188 max=0 total=0 [2017-06-20 05:50:53.016379] I [MSGID: 101053] [mem-pool.c:641:mem_pool_destroy] 0-gv0-readdir-ahead: size=60 max=0 total=0 [2017-06-20 05:50:53.016392] I [MSGID: 101053] [mem-pool.c:641:mem_pool_destroy] 0-gv0-io-cache: size=68 max=2 total=2 [2017-06-20 05:50:53.016402] I [MSGID: 101053] [mem-pool.c:641:mem_pool_destroy] 0-gv0-io-cache: size=252 max=2 total=11 [2017-06-20 05:50:53.016432] I [io-stats.c:3822:fini] 0-gv0: io-stats translator unloaded [2017-06-20 05:50:53.016651] I [MSGID: 101191] [event-epoll.c:659:event_dispatch_epoll_worker] 0-epoll: Exited thread with index 2 [2017-06-20 05:50:53.016688] I [MSGID: 101191] [event-epoll.c:659:event_dispatch_epoll_worker] 0-epoll: Exited thread with index 1 image: gluster://bootp-73-199-197.lab.eng.pek2.redhat.com:0/gv0/win2016-64-virtio-scsi.qcow2 file format: qcow2 virtual size: 30G (32212254720 bytes) disk size: 9.5G cluster_size: 65536 Format specific information: compat: 1.1 lazy refcounts: false refcount bits: 16 corrupt: false /dev/mapper/rhel_intel--3323--24--2-root 52403200 15057960 37345240 29% / devtmpfs 12314352 0 12314352 0% /dev tmpfs 12342508 12 12342496 1% /dev/shm tmpfs 12342508 25148 12317360 1% /run tmpfs 12342508 0 12342508 0% /sys/fs/cgroup /dev/sda1 1038336 255792 782544 25% /boot /dev/mapper/rhel_intel--3323--24--2-home 178183164 783920 177399244 1% /home bootp-73-199-200.lab.eng.pek2.redhat.com:/gv0 97608448 24135040 73473408 25% /mnt/gluster fail to reproduce with the latest version. |