Bug 1481142
| Summary: | fencing-device not properly registered after disable/enable cycle [rhel-7.4.z] | ||
|---|---|---|---|
| Product: | Red Hat Enterprise Linux 7 | Reporter: | Oneata Mircea Teodor <toneata> |
| Component: | pacemaker | Assignee: | Ken Gaillot <kgaillot> |
| Status: | CLOSED ERRATA | QA Contact: | cluster-qe <cluster-qe> |
| Severity: | urgent | Docs Contact: | |
| Priority: | urgent | ||
| Version: | 7.4 | CC: | abeekhof, aherr, cfeist, cluster-maint, jruemker, kgaillot, kwenning, mjuricek, mnovacek, nbarcet, sfroemer |
| Target Milestone: | rc | Keywords: | ZStream |
| Target Release: | 7.4 | ||
| Hardware: | Unspecified | ||
| OS: | Unspecified | ||
| Whiteboard: | |||
| Fixed In Version: | pacemaker-1.1.16-12.el7_4.1 | Doc Type: | Bug Fix |
| Doc Text: |
Previously, Pacemaker's stonithd service used an incorrect search pattern when checking the configuration for re-enabled fence devices. Consequently, re-enabled fence devices were shown to be available only on the node where they had been started. With this update, stonithd now uses the correct search pattern, and the described problem no longer occurs.
|
Story Points: | --- |
| Clone Of: | 1474463 | Environment: | |
| Last Closed: | 2017-09-05 11:31:54 UTC | Type: | --- |
| Regression: | --- | Mount Type: | --- |
| Documentation: | --- | CRM: | |
| Verified Versions: | Category: | --- | |
| oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
| Cloudforms Team: | --- | Target Upstream Version: | |
| Embargoed: | |||
| Bug Depends On: | 1474463 | ||
| Bug Blocks: | |||
|
Description
Oneata Mircea Teodor
2017-08-14 08:26:37 UTC
Testing procedure (from parent bug): 1. Configure a cluster with a fencing device (with no rules). 2. Restart the cluster, and wait until the fencing device is started. 3. Use 'stonith_admin -L' to verify that the fencing device is available on both the node where it is started and at least one other node. 4. Disable and re-enable the fencing device with pcs, and wait until it is started again. 5. Run 'stonith_admin -L' again. Before the fix, it will show the fencing device as available only on the node where it is started. After the fix, it will show the device as available on all nodes. Since the problem described in this bug report should be resolved in a recent advisory, it has been closed with a resolution of ERRATA. For information on the advisory, and where to find the updated files, follow the link below. If the solution does not work for you, open a new bug report. https://access.redhat.com/errata/RHBA-2017:2587 |