Bug 1516685
| Summary: | No alerts related to brick utilization | ||
|---|---|---|---|
| Product: | [Red Hat Storage] Red Hat Gluster Storage | Reporter: | Filip Balák <fbalak> |
| Component: | web-admin-tendrl-notifier | Assignee: | gowtham <gshanmug> |
| Status: | CLOSED ERRATA | QA Contact: | Martin Kudlej <mkudlej> |
| Severity: | unspecified | Docs Contact: | |
| Priority: | unspecified | ||
| Version: | rhgs-3.3 | CC: | gshanmug, mkudlej, nthomas, rhs-bugs, sanandpa, sankarshan |
| Target Milestone: | --- | Keywords: | ZStream |
| Target Release: | --- | ||
| Hardware: | Unspecified | ||
| OS: | Unspecified | ||
| Whiteboard: | |||
| Fixed In Version: | tendrl-gluster-integration-1.5.4-6.el7rhgs.noarch tendrl-monitoring-integration-1.5.4-8.el7rhgs.noarch | Doc Type: | If docs needed, set a value |
| Doc Text: | Story Points: | --- | |
| Clone Of: | Environment: | ||
| Last Closed: | 2017-12-18 04:37:58 UTC | Type: | Bug |
| Regression: | --- | Mount Type: | --- |
| Documentation: | --- | CRM: | |
| Verified Versions: | Category: | --- | |
| oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
| Cloudforms Team: | --- | Target Upstream Version: | |
| Embargoed: | |||
This issue is fixed https://bugzilla.redhat.com/show_bug.cgi?id=1516685 Verified with: etcd-3.2.7-1.el7.x86_64 glusterfs-3.8.4-52.el7_4.x86_64 glusterfs-3.8.4-52.el7rhgs.x86_64 glusterfs-api-3.8.4-52.el7rhgs.x86_64 glusterfs-cli-3.8.4-52.el7rhgs.x86_64 glusterfs-client-xlators-3.8.4-52.el7_4.x86_64 glusterfs-client-xlators-3.8.4-52.el7rhgs.x86_64 glusterfs-events-3.8.4-52.el7rhgs.x86_64 glusterfs-fuse-3.8.4-52.el7_4.x86_64 glusterfs-fuse-3.8.4-52.el7rhgs.x86_64 glusterfs-geo-replication-3.8.4-52.el7rhgs.x86_64 glusterfs-libs-3.8.4-52.el7_4.x86_64 glusterfs-libs-3.8.4-52.el7rhgs.x86_64 glusterfs-rdma-3.8.4-52.el7rhgs.x86_64 glusterfs-server-3.8.4-52.el7rhgs.x86_64 gluster-nagios-addons-0.2.10-2.el7rhgs.x86_64 gluster-nagios-common-0.2.4-1.el7rhgs.noarch libvirt-daemon-driver-storage-gluster-3.2.0-14.el7_4.3.x86_64 python-etcd-0.4.5-1.el7rhgs.noarch python-gluster-3.8.4-52.el7rhgs.noarch rubygem-etcd-0.3.0-1.el7rhgs.noarch tendrl-ansible-1.5.4-2.el7rhgs.noarch tendrl-api-1.5.4-3.el7rhgs.noarch tendrl-api-httpd-1.5.4-3.el7rhgs.noarch tendrl-collectd-selinux-1.5.4-1.el7rhgs.noarch tendrl-commons-1.5.4-5.el7rhgs.noarch tendrl-gluster-integration-1.5.4-6.el7rhgs.noarch tendrl-grafana-plugins-1.5.4-8.el7rhgs.noarch tendrl-grafana-selinux-1.5.4-1.el7rhgs.noarch tendrl-monitoring-integration-1.5.4-8.el7rhgs.noarch tendrl-node-agent-1.5.4-8.el7rhgs.noarch tendrl-notifier-1.5.4-5.el7rhgs.noarch tendrl-selinux-1.5.4-1.el7rhgs.noarch tendrl-ui-1.5.4-4.el7rhgs.noarch vdsm-gluster-4.17.33-1.2.el7rhgs.noarch Since the problem described in this bug report should be resolved in a recent advisory, it has been closed with a resolution of ERRATA. For information on the advisory, and where to find the updated files, follow the link below. If the solution does not work for you, open a new bug report. https://access.redhat.com/errata/RHEA-2017:3478 |
Description of problem: There are no alerts related to brick utilization. I have filled volume with files. Volume utilization alerts showed correctly but there are no messages about bricks which breached threshold. Version-Release number of selected component (if applicable): tendrl-ansible-1.5.4-1.el7rhgs.noarch tendrl-ui-1.5.4-4.el7rhgs.noarch tendrl-grafana-plugins-1.5.4-5.el7rhgs.noarch tendrl-selinux-1.5.3-2.el7rhgs.noarch tendrl-commons-1.5.4-4.el7rhgs.noarch tendrl-api-1.5.4-2.el7rhgs.noarch tendrl-api-httpd-1.5.4-2.el7rhgs.noarch tendrl-monitoring-integration-1.5.4-5.el7rhgs.noarch tendrl-grafana-selinux-1.5.3-2.el7rhgs.noarch tendrl-node-agent-1.5.4-5.el7rhgs.noarch tendrl-notifier-1.5.4-3.el7rhgs.noarch How reproducible: 100% Steps to Reproduce: 1. Import cluster with volume into tendrl. 2. Ensure that tendrl user has valid mail and enabled notifications. 3. Mount volume on client. 4. Start checking snmp messages: # journalctl -u snmptrapd -fe 5. Fill volume with files: # for i in {1..N-1}; do dd if=/dev/zero of=/[MOUNT]/testfile$i bs=1G count=1; done where N is capacity in GiB and [MOUNT] is directory with mounted volume. 6. Check for mails. 7. Check alerts in tendrl. Actual results: There is alert related Volume utilization but no alerts related to bricks. Expected results: There should be alerts for bricks that breach capacity threshold. Additional info: