Summary: [Backport][OSP13][RFE] Take into account NUMA locality of physical NICs when plugging instance VIFS from Neutron networks
Product: Red Hat OpenStack Reporter: Aviv Guetta <aguetta>
Component: openstack-novaAssignee: Stephen Finucane <stephenfin>
Status: CLOSED ERRATA QA Contact: Maxim Babushkin <mbabushk>
Severity: high Docs Contact:
Priority: urgent    
Version: 13.0 (Queens)CC: aconole, aguetta, atragler, bcafarel, chrisw, cpaquin, dasmith, dcadzow, djuran, egallen, eglynn, fbaudin, fherrman, fiezzi, fleitner, jhakimra, jhsiao, jniu, jraju, jschluet, kchamart, ktraynor, lyarwood, marjones, markmc, mbabushk, mschuppe, rcain, rheslop, rkhan, sbauza, sgordon, sputhenp, srevivo, stephenfin, supadhya, trozet, tvvcox, vcojot, vkhitrin, vromanso, weiyongjun
Target Milestone: z7Keywords: FeatureBackport, FutureFeature, Triaged, ZStream
Target Release: 13.0 (Queens)   
Hardware: All   
OS: Linux   
Whiteboard:
Fixed In Version: openstack-nova-17.0.9-11.el7ost Doc Type: Enhancement
Doc Text:
With this update you can now configure NUMA affinity to ensure instances are placed on the same NUMA node as the NIC providing external connectivity for the vSwitch. This feature is available for layer 2 networks of type 'flat' or 'vlan' and layer 3 networks of type 'vxlan', 'gre', or 'geneve'.
Story Points: ---
Clone Of: 1187945
: 1780141 (view as bug list) Environment:
Last Closed: 2019-07-10 13:01:53 UTC Type: Bug
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:
Bug Depends On: 1187945, 1593645, 1660947, 1696658, 1696663, 1782218    
Bug Blocks: 1476900, 1500557, 1611997, 1780141    

Comment 4 Jon Schlueter 2019-04-05 14:44:56 UTC
can we get a non-private summary of this RFE please?

Comment 5 Stephen Finucane 2019-04-23 09:09:54 UTC
This tracks effort to backport the NUMA-aware vSwitches feature added in OSP 14 (rhbz 1187945) to OSP 13. In summary, physical NICs typically use the PCIe interface and have an association with a host NUMA node. This feature allows us to associate networks using a given NIC with that NIC's NUMA node and therefore associate any instances using these networks with the same NUMA node.

Comment 18 errata-xmlrpc 2019-07-10 13:01:53 UTC
Since the problem described in this bug report should be
resolved in a recent advisory, it has been closed with a
resolution of ERRATA.

For information on the advisory, and where to find the updated
files, follow the link below.

If the solution does not work for you, open a new bug report.

https://access.redhat.com/errata/RHBA-2019:1740