Bug 1619293
Summary: | [free-int] installer should error if non-openshift-* namespace is configured for logging and priorityClass is going to be set | ||
---|---|---|---|
Product: | OpenShift Container Platform | Reporter: | Justin Pierce <jupierce> |
Component: | Installer | Assignee: | ewolinet |
Status: | CLOSED ERRATA | QA Contact: | Anping Li <anli> |
Severity: | unspecified | Docs Contact: | |
Priority: | unspecified | ||
Version: | 3.11.0 | CC: | aos-bugs, jcantril, jokerman, mmccomas |
Target Milestone: | --- | ||
Target Release: | 3.11.0 | ||
Hardware: | Unspecified | ||
OS: | Unspecified | ||
Whiteboard: | |||
Fixed In Version: | Doc Type: | Bug Fix | |
Doc Text: |
Cause: If logging was not in a namespace that began with 'openshift-' Fluentd was not able to use the "system-cluster-critical" priority class.
Consequence: Fluentd would not be able to start up.
Fix: We create a priority class for Cluster Logging and configure Fluentd to use that instead.
Result: Fluentd is able to start up, even if not installed to an 'openshift-*' namespace.
|
Story Points: | --- |
Clone Of: | Environment: | ||
Last Closed: | 2018-10-11 07:25:25 UTC | Type: | Bug |
Regression: | --- | Mount Type: | --- |
Documentation: | --- | CRM: | |
Verified Versions: | Category: | --- | |
oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
Cloudforms Team: | --- | Target Upstream Version: | |
Embargoed: |
Description
Justin Pierce
2018-08-20 14:23:38 UTC
Instead of failing with an error, we will be creating a priority class for fluentd to use instead. https://github.com/openshift/openshift-ansible/pull/9686 The bug have been fix in v3.11.0-0.28.0.0 Since the problem described in this bug report should be resolved in a recent advisory, it has been closed with a resolution of ERRATA. For information on the advisory, and where to find the updated files, follow the link below. If the solution does not work for you, open a new bug report. https://access.redhat.com/errata/RHBA-2018:2652 |