Bug 162966

Summary: Fencing is not working with APC AP 9225 Masterswitch
Product: [Retired] Red Hat Cluster Suite Reporter: Lon Hohberger <lhh>
Component: clumanagerAssignee: Lon Hohberger <lhh>
Status: CLOSED ERRATA QA Contact: Cluster QE <mspqa-list>
Severity: medium Docs Contact:
Priority: medium    
Version: 3CC: cluster-maint, jbacik
Target Milestone: ---   
Target Release: ---   
Hardware: All   
OS: Linux   
Whiteboard:
Fixed In Version: RHBA-2005-676 Doc Type: Bug Fix
Doc Text:
Story Points: ---
Clone Of: Environment:
Last Closed: 2005-09-30 14:57:41 UTC Type: ---
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:
Bug Depends On:    
Bug Blocks: 162166    
Attachments:
Description Flags
Fixes STONITH driver none

Description Lon Hohberger 2005-07-11 21:28:52 UTC
The newer firmware of the APC MasterSwitch AP9225 with the newer Web/SNMP card
doesn't work with our STONITH driver (apcmaster).  This is because of a string
which is slightly different:

e.g.

"MSP APP"

versus

"MasterSwitch plus APP"

Comment 1 Lon Hohberger 2005-07-11 21:28:52 UTC
Created attachment 116628 [details]
Fixes STONITH driver

Comment 6 Lon Hohberger 2005-07-15 14:27:40 UTC
1.2.27pre1-1 is available from:

http://people.redhat.com/lhh/packages.html

It should address this issue.  This package should be used for testing only.

Comment 9 Red Hat Bugzilla 2005-09-30 14:57:44 UTC
An advisory has been issued which should help the problem
described in this bug report. This report is therefore being
closed with a resolution of ERRATA. For more information
on the solution and/or where to find the updated files,
please follow the link below. You may reopen this bug report
if the solution does not work for you.

http://rhn.redhat.com/errata/RHBA-2005-676.html