Bug 2073890 (CVE-2022-1319)

Summary: CVE-2022-1319 undertow: Double AJP response for 400 from EAP 7 results in CPING failures
Product: [Other] Security Response Reporter: Sandipan Roy <saroy>
Component: vulnerabilityAssignee: Red Hat Product Security <security-response-team>
Status: CLOSED ERRATA QA Contact:
Severity: medium Docs Contact:
Priority: medium    
Version: unspecifiedCC: aboyko, aileenc, alazarot, anstephe, asoldano, avibelli, bbaranow, bgeorges, bmaxwell, boliveir, brian.stansberry, cdewolf, chazlett, clement.escoffier, cmoulliard, dandread, darran.lofthouse, dkreling, dosoudil, drieden, eglynn, emingora, eric.wittmann, etirelli, fjuma, ggaughan, gmalinko, gsmet, hamadhan, hbraun, ibek, ikanello, iweiss, janstey, jjoyce, jnethert, jochrist, jrokos, jstastny, jwon, krathod, kverlaen, lgao, lhh, lpeer, lthon, mburns, mkolesni, mnovotny, mosmerov, msochure, msvehla, mszynkie, nwallace, pantinor, pdelbell, pdrozd, peholase, pgallagh, pjindal, pmackay, probinso, rguimara, rrajasek, rruss, rstancel, rsvoboda, sbiarozk, scohen, sdouglas, smaestri, spower, steve.beattie, sthorger, tom.jenkinson, tzimanyi
Target Milestone: ---Keywords: Security
Target Release: ---   
Hardware: All   
OS: Linux   
Whiteboard:
Fixed In Version: Doc Type: If docs needed, set a value
Doc Text:
A flaw was found in Undertow. For an AJP 400 response, EAP 7 is improperly sending two response packets, and those packets have the reuse flag set even though JBoss EAP closes the connection. A failure occurs when the connection is reused after a 400 by CPING since it reads in the second SEND_HEADERS response packet instead of a CPONG.
Story Points: ---
Clone Of: Environment:
Last Closed: 2022-06-06 20:32:19 UTC Type: ---
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:
Bug Depends On:    
Bug Blocks: 2073892, 2074387    

Description Sandipan Roy 2022-04-11 04:31:39 UTC
For an AJP 400 response, EAP 7 is improperly sending two response packets and those 'END RESPONSE' packets have the reuse flag set even though JBoss does close the connection. So when httpd reuses that connection after a 400 for something like a cping, it will receive a failure since it reads in the second SEND_HEADERS response packet instead of a CPONG.

Comment 6 errata-xmlrpc 2022-06-06 15:12:31 UTC
This issue has been addressed in the following products:

  Red Hat JBoss Enterprise Application Platform

Via RHSA-2022:4922 https://access.redhat.com/errata/RHSA-2022:4922

Comment 7 errata-xmlrpc 2022-06-06 15:52:49 UTC
This issue has been addressed in the following products:

  Red Hat JBoss Enterprise Application Platform 7.4 on RHEL 7

Via RHSA-2022:4918 https://access.redhat.com/errata/RHSA-2022:4918

Comment 8 errata-xmlrpc 2022-06-06 15:59:17 UTC
This issue has been addressed in the following products:

  Red Hat JBoss Enterprise Application Platform 7.4 for RHEL 8

Via RHSA-2022:4919 https://access.redhat.com/errata/RHSA-2022:4919

Comment 9 Product Security DevOps Team 2022-06-06 20:32:16 UTC
This bug is now closed. Further updates for individual products will be reflected on the CVE page(s):

https://access.redhat.com/security/cve/cve-2022-1319

Comment 10 errata-xmlrpc 2022-07-07 14:23:00 UTC
This issue has been addressed in the following products:

  Red Hat Fuse 7.11

Via RHSA-2022:5532 https://access.redhat.com/errata/RHSA-2022:5532

Comment 11 errata-xmlrpc 2022-12-14 13:17:35 UTC
This issue has been addressed in the following products:

  Red Hat Openshift Application Runtimes

Via RHSA-2022:8761 https://access.redhat.com/errata/RHSA-2022:8761