Bug 2098392

Summary: [OCP 4.11] Ironic cannot match "wwn" rootDeviceHint for a multipath device
Product: OpenShift Container Platform Reporter: Ivan Bodunov <ibodunov>
Component: Bare Metal Hardware ProvisioningAssignee: Dmitry Tantsur <dtantsur>
Bare Metal Hardware Provisioning sub component: ironic QA Contact: Lubov <lshilin>
Status: CLOSED ERRATA Docs Contact:
Severity: urgent    
Priority: urgent CC: dtantsur, lshilin, rpittau
Version: 4.8Keywords: OtherQA, Triaged
Target Milestone: ---   
Target Release: 4.11.0   
Hardware: x86_64   
OS: Unspecified   
Whiteboard:
Fixed In Version: openstack-ironic-python-agent-8.6.1-0.20220623075054.1d50c23.el8 Doc Type: Bug Fix
Doc Text:
Cause: ironic fails to match wwn/serial numbers to multipath devices Consequence: wwn/serial numbers for devicemapper devices can't be used as hint for system installation in install-config.yaml Fix: ironic now recognizes wwn/serial number as unique identifiers for multipath devices Result: it is now possible to use wwn/serial numbers for devicemapper devices as hint for system installation in install-config.yaml
Story Points: ---
Clone Of:
: 2100775 (view as bug list) Environment:
Last Closed: 2022-08-10 11:18:42 UTC Type: Bug
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:
Bug Depends On:    
Bug Blocks: 2100775    

Comment 8 errata-xmlrpc 2022-08-10 11:18:42 UTC
Since the problem described in this bug report should be
resolved in a recent advisory, it has been closed with a
resolution of ERRATA.

For information on the advisory (Important: OpenShift Container Platform 4.11.0 bug fix and security update), and where to find the updated
files, follow the link below.

If the solution does not work for you, open a new bug report.

https://access.redhat.com/errata/RHSA-2022:5069