Summary: [GSS] [4.11.z-Clone] ceph cluster unresponsive when 2 nodes of same zone is down in stretch cluster
Product: [Red Hat Storage] Red Hat OpenShift Data Foundation Reporter: Sunil Kumar Acharya <sheggodu>
Component: rookAssignee: Travis Nielsen <tnielsen>
Status: CLOSED ERRATA QA Contact: Mahesh Shetty <mashetty>
Severity: high Docs Contact:
Priority: unspecified    
Version: 4.10CC: agantony, bkunal, bniver, etamir, hnallurv, jfindysz, kramdoss, madam, mashetty, mhackett, mmuench, muagarwa, ocs-bugs, odf-bz-bot, pdhange, pdhiran, racpatel, sarora, srai, tdesala, tnielsen, vkolli, vumrao
Target Milestone: ---   
Target Release: ODF 4.11.1   
Hardware: x86_64   
OS: Linux   
Whiteboard:
Fixed In Version: Doc Type: Bug Fix
Doc Text:
Previously, two MONs could end up on the same node instead of being spread across unique nodes. This happened when the operator was restarted in the middle of a MON failover, multiple MONs could be started on the same node, which reduced the MON quorum availability. With this update, the operator properly cancels the MON failover if the MON failover times out, and ensures that any extra MONs are removed based on the stretch topology or multiple MONs that run on the same node.
Story Points: ---
Clone Of: 2113062 Environment:
Last Closed: 2022-09-14 15:15:05 UTC Type: ---
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:
Bug Depends On: 2113062, 2120601    
Bug Blocks:    

Comment 16 errata-xmlrpc 2022-09-14 15:15:05 UTC
Since the problem described in this bug report should be
resolved in a recent advisory, it has been closed with a
resolution of ERRATA.

For information on the advisory (Red Hat OpenShift Data Foundation 4.11.1 Bug Fix Update), and where to find the updated
files, follow the link below.

If the solution does not work for you, open a new bug report.

https://access.redhat.com/errata/RHBA-2022:6525