Bug 2140550

Summary: [RDR] (Failover when primary down) Once primary cluster nodes are powered on, cleanup stuck due to VRG,VRs unable to transition to Secondary
Product: [Red Hat Storage] Red Hat OpenShift Data Foundation Reporter: Sidhant Agrawal <sagrawal>
Component: cephAssignee: Neha Ojha <nojha>
ceph sub component: RADOS QA Contact: Elad <ebenahar>
Status: CLOSED DUPLICATE Docs Contact:
Severity: high    
Priority: unspecified CC: bniver, ebenahar, idryomov, kramdoss, madam, mrajanna, muagarwa, nmordech, nojha, ocs-bugs, odf-bz-bot, pdhange, pdhiran, shan, sheggodu, srangana, sseshasa, tnielsen
Version: 4.12Keywords: Automation
Target Milestone: ---   
Target Release: ---   
Hardware: Unspecified   
OS: Unspecified   
Whiteboard:
Fixed In Version: Doc Type: If docs needed, set a value
Doc Text:
Story Points: ---
Clone Of: Environment:
Last Closed: 2022-12-07 22:01:31 UTC Type: Bug
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:
Bug Depends On:    
Bug Blocks: 2115507    

Comment 19 Elad 2022-11-14 07:33:13 UTC
Proposing as a blocker as per comment #14

Comment 23 Sébastien Han 2022-11-15 08:15:15 UTC
The only thing I can think of is that the OSD is slow to start and it's not responding to socket commands in time, thus the probe fails.

Comment 32 Prashant Dhange 2022-12-07 22:01:31 UTC

*** This bug has been marked as a duplicate of bug 2139103 ***