Bug 2180493

Summary: [GSS] Vague warning of VolumeResizeFailed on successful PVC expansion
Product: [Red Hat Storage] Red Hat OpenShift Data Foundation Reporter: Sonal <sarora>
Component: csi-driverAssignee: Madhu Rajanna <mrajanna>
Status: CLOSED NOTABUG QA Contact: krishnaram Karthick <kramdoss>
Severity: medium Docs Contact:
Priority: unspecified    
Version: 4.10CC: hekumar, hnallurv, ocs-bugs, odf-bz-bot
Target Milestone: ---Flags: sarora: needinfo? (hekumar)
Target Release: ---   
Hardware: x86_64   
OS: Linux   
Whiteboard:
Fixed In Version: Doc Type: If docs needed, set a value
Doc Text:
Story Points: ---
Clone Of: Environment:
Last Closed: 2023-03-29 09:25:56 UTC Type: Bug
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:

Description Sonal 2023-03-21 14:59:37 UTC
Description of problem (please be detailed as possible and provide log
snippests):

After cephfs PVC is resized, below warning is observed in the events:

0s          Warning   VolumeResizeFailed            pod/test-xxx                   NodeExpandVolume.NodeExpandVolume failed for volume "pvc-yyy" : Expander.NodeExpand found CSI plugin kubernetes.io/csi/openshift-storage.cephfs.csi.ceph.com to not support node expansion


Version of all relevant components (if applicable):
ODF 4.10.10

Does this issue impact your ability to continue to work with the product
(please explain in detail what is the user impact)?
No, the warning creates confusion as the PVC was expanded successfully.

Is there any workaround available to the best of your knowledge?
Ignore the warning

Rate from 1 - 5 the complexity of the scenario you performed that caused this
bug (1 - very simple, 5 - very complex)?
1

Can this issue reproducible?
Yes

Can this issue reproduce from the UI?
Yes

If this is a regression, please provide more details to justify this:
-

Steps to Reproduce:
1. Create cephfs PVC
2. Expand it from GUI or by editing pvc yaml


Actual results:
PVC got expanded, however warning says VolumeResizeFailed.

Expected results:
There should not be such warning if PVC is resized successfully.

Additional info: