Bug 2187426
| Summary: | [BDI] Pacemaker resources left UNCLEAN after controller node failure [rhel-9.0.0.z] | ||
|---|---|---|---|
| Product: | Red Hat Enterprise Linux 9 | Reporter: | RHEL Program Management Team <pgm-rhel-tools> |
| Component: | pacemaker | Assignee: | Klaus Wenninger <kwenning> |
| Status: | CLOSED ERRATA | QA Contact: | cluster-qe <cluster-qe> |
| Severity: | urgent | Docs Contact: | |
| Priority: | high | ||
| Version: | 9.3 | CC: | cfeist, cluster-maint, kgaillot, kwenning, lmiccini, matteo.panella, mjuricek, nwahl, rbruzzon, sbradley |
| Target Milestone: | rc | Keywords: | Triaged, ZStream |
| Target Release: | --- | Flags: | pm-rhel:
mirror+
|
| Hardware: | x86_64 | ||
| OS: | All | ||
| Whiteboard: | |||
| Fixed In Version: | pacemaker-2.1.2-4.el9_0.4 | Doc Type: | Bug Fix |
| Doc Text: |
Cause: When fence_watchdog is used in a topology after another fencing device, the watchdog timeout would not be considered when calculating the timeout for the fencing operation.
Consequence: If the first device timed out, the fencing operation could time out even though the watchdog would fence the node.
Fix: The watchdog timeout is now included in the fencing operation timeout.
Result: The fencing operation succeeds even if the first device times out.
|
Story Points: | --- |
| Clone Of: | 2182482 | Environment: | |
| Last Closed: | 2023-08-29 09:24:42 UTC | Type: | Bug |
| Regression: | --- | Mount Type: | --- |
| Documentation: | --- | CRM: | |
| Verified Versions: | Category: | --- | |
| oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
| Cloudforms Team: | --- | Target Upstream Version: | 2.1.6 |
| Embargoed: | |||
| Bug Depends On: | 2182482 | ||
| Bug Blocks: | |||
|
Comment 11
errata-xmlrpc