Bug 2187426

Summary: [BDI] Pacemaker resources left UNCLEAN after controller node failure [rhel-9.0.0.z]
Product: Red Hat Enterprise Linux 9 Reporter: RHEL Program Management Team <pgm-rhel-tools>
Component: pacemakerAssignee: Klaus Wenninger <kwenning>
Status: VERIFIED --- QA Contact: cluster-qe <cluster-qe>
Severity: urgent Docs Contact:
Priority: high    
Version: 9.3CC: cfeist, cluster-maint, kgaillot, kwenning, lmiccini, matteo.panella, mjuricek, nwahl, rbruzzon, sbradley
Target Milestone: rcKeywords: Triaged, ZStream
Target Release: ---   
Hardware: x86_64   
OS: All   
Whiteboard:
Fixed In Version: pacemaker-2.1.2-4.el9_0.4 Doc Type: Bug Fix
Doc Text:
Cause: When fence_watchdog is used in a topology after another fencing device, the watchdog timeout would not be considered when calculating the timeout for the fencing operation. Consequence: If the first device timed out, the fencing operation could time out even though the watchdog would fence the node. Fix: The watchdog timeout is now included in the fencing operation timeout. Result: The fencing operation succeeds even if the first device times out.
Story Points: ---
Clone Of: 2182482 Environment:
Last Closed: Type: Bug
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version: 2.1.6
Embargoed:
Bug Depends On: 2182482    
Bug Blocks: