Bug 2192913

Summary: [OVN+VLAN+DVR] Flooded packets testing e/w with different tenant networks [Core OVN tracker]
Product: Red Hat OpenStack Reporter: Eduardo Olivares <eolivare>
Component: openstack-neutronAssignee: Jakub Libosvar <jlibosva>
Status: POST --- QA Contact: Eran Kuris <ekuris>
Severity: medium Docs Contact:
Priority: medium    
Version: 17.1 (Wallaby)CC: chrisw, ifrangs, jamsmith, jelynch, jlibosva, ltomasbo, scohen, vkhitrin
Target Milestone: z1Keywords: TestOnly, Triaged
Target Release: 17.1Flags: ifrangs: needinfo? (jlibosva)
Hardware: Unspecified   
OS: Unspecified   
Whiteboard:
Fixed In Version: Doc Type: Known Issue
Doc Text:
In RHOSP environments with ML2/OVN or ML2/OVS that have DVR enabled and use VLAN tenant networks, east/west traffic between instances connected to different tenant networks is flooded to the fabric. + As a result, packets between those instances reach not only the Compute nodes where those instances run, but also any other overcloud node. + This could cause an impact on the network and it could be a security risk because the fabric sends traffic everywhere. + This bug will be fixed in a later FDP release. You do not need to perform a RHOSP update to obtain the FDP fix.
Story Points: ---
Clone Of: Environment:
Last Closed: Type: Bug
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:
Bug Depends On: 2087779    
Bug Blocks: