Summary: CephNodeDown Alert not triggered when Worker node Is gracefully stopped
Product: [Red Hat Storage] Red Hat OpenShift Data Foundation Reporter: Daniel Osypenko <dosypenk>
Component: ceph-monitoringAssignee: Nishanth Thomas <nthomas>
Status: NEW --- QA Contact: Harish NV Rao <hnallurv>
Severity: high Docs Contact:
Priority: unspecified    
Version: 4.17CC: odf-bz-bot
Target Milestone: ---   
Target Release: ---   
Hardware: Unspecified   
OS: Unspecified   
Whiteboard:
Fixed In Version: Doc Type: If docs needed, set a value
Doc Text:
Story Points: ---
Clone Of: Environment:
Last Closed: Type: Bug
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:

Description Daniel Osypenko 2024-10-28 17:19:52 UTC
Description of problem (please be detailed as possible and provide log
snippests):

`test_stop_start_node_validate_topology` constantly fails on multiple deployments.
CephNodeDown alert is not firing after 30s and not visible both via Prometheus and management-console. Issue detected on vSphere clusters.

**Failed: One or multiple checks did not pass:**

| Check                                                        | check_state |
|--------------------------------------------------------------|-------------|
| prometheus_CephNodeDown_alert_fired                         | 0           |
| cluster_in_danger_state_check_pass                          | 1           |
| ceph_node_down_alert_found_check_pass                       | 0           |
| ceph_node_down_alert_found_on_idle_node_check_pass          | 1           |
| prometheus_CephNodeDown_alert_removed                       | 1           |
| ceph_node_down_alert_found_after_node_turned_on_check_pass  | 1           |


Version of all relevant components (if applicable):
ODF 4.17.0-105, OCP 4.17

Does this issue impact your ability to continue to work with the product
(please explain in detail what is the user impact)?
in some cases

Is there any workaround available to the best of your knowledge?
no

Rate from 1 - 5 the complexity of the scenario you performed that caused this
bug (1 - very simple, 5 - very complex)?
2

Can this issue reproducible?
yes

Can this issue reproduce from the UI?
yes

If this is a regression, please provide more details to justify this:
regression. We had successful test executions, but a long ago. no history saved.

Steps to Reproduce:
1. Turn off the node from VMWare console or in other way
2. login to management console and verify CephNodeDown alert appeared or make a prometheus request to fetch fired alerts with req
curl -k -H "Authorization: Bearer $TOKEN" -X GET https://$ROUTE/api/v1/alerts | jq '.data.alerts[].labels.alertname'
3. 


Actual results:
CephNodeDown fail to fire

Expected results:
CephNodeDown fires when one ceph node is down for 30+sec

Additional info:
OCP and OCS must-gather logs https://url.corp.redhat.com/2a64b06