Summary: CVE-2026-43203 kernel: atm: fore200e: fix use-after-free in tasklets during device removal
Product: [Other] Security Response Reporter: OSIDB Bzimport <bzimport>
Component: vulnerabilityAssignee: Product Security <prodsec-ir-bot>
Status: NEW --- QA Contact:
Severity: low Docs Contact:
Priority: low    
Version: unspecifiedCC: rhel-process-autobot, watson-tool-maintainers
Target Milestone: ---Keywords: Security
Target Release: ---   
Hardware: All   
OS: Linux   
Whiteboard:
Fixed In Version: Doc Type: ---
Doc Text:
A flaw was found in the Linux kernel's fore200e ATM (Asynchronous Transfer Mode) network adapter driver. A race condition during the device removal process can lead to a use-after-free vulnerability. This occurs when the fore200e adapter is deallocated while its associated tasklets (small, interrupt-driven functions) are still running or pending, causing the system to access freed memory. This issue can result in system instability or a denial of service.
Story Points: ---
Clone Of: Environment:
Last Closed: Type: ---
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:

Description OSIDB Bzimport 2026-05-06 13:08:36 UTC
In the Linux kernel, the following vulnerability has been resolved:

atm: fore200e: fix use-after-free in tasklets during device removal

When the PCA-200E or SBA-200E adapter is being detached, the fore200e
is deallocated. However, the tx_tasklet or rx_tasklet may still be running
or pending, leading to use-after-free bug when the already freed fore200e
is accessed again in fore200e_tx_tasklet() or fore200e_rx_tasklet().

One of the race conditions can occur as follows:

CPU 0 (cleanup)           | CPU 1 (tasklet)
fore200e_pca_remove_one() | fore200e_interrupt()
  fore200e_shutdown()     |   tasklet_schedule()
    kfree(fore200e)       | fore200e_tx_tasklet()
                          |   fore200e-> // UAF

Fix this by ensuring tx_tasklet or rx_tasklet is properly canceled before
the fore200e is released. Add tasklet_kill() in fore200e_shutdown() to
synchronize with any pending or running tasklets. Moreover, since
fore200e_reset() could prevent further interrupts or data transfers,
the tasklet_kill() should be placed after fore200e_reset() to prevent
the tasklet from being rescheduled in fore200e_interrupt(). Finally,
it only needs to do tasklet_kill() when the fore200e state is greater
than or equal to FORE200E_STATE_IRQ, since tasklets are uninitialized
in earlier states. In a word, the tasklet_kill() should be placed in
the FORE200E_STATE_IRQ branch within the switch...case structure.

This bug was identified through static analysis.