Bug 2514439 (CVE-2026-68429)

Summary: CVE-2026-68429 kernel: drm/dp_mst: Handle torn-down topology gracefully in drm_dp_mst_topology_queue_probe()
Product: [Other] Security Response Reporter: OSIDB Bzimport <bzimport>
Component: vulnerabilityAssignee: Product Security <prodsec-ir-bot>
Status: NEW --- QA Contact:
Severity: low Docs Contact:
Priority: low    
Version: unspecifiedCC: rhel-process-autobot, watson-tool-maintainers
Target Milestone: ---Keywords: Security
Target Release: ---   
Hardware: All   
OS: Linux   
Whiteboard:
Fixed In Version: Doc Type: ---
Doc Text:
A flaw was found in the Linux kernel's DisplayPort (DP) Multi-Stream Transport (MST) module. A race condition can occur during hotplug or link-loss events when the MST topology is being torn down while the `drm_dp_mst_topology_queue_probe()` function is called. This can lead to spurious kernel warnings and cause the display compositor to crash when connecting or disconnecting DP MST monitors, resulting in a denial of service.
Story Points: ---
Clone Of: Environment:
Last Closed: Type: ---
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:

Description OSIDB Bzimport 2026-08-12 00:21:24 UTC
In the Linux kernel, the following vulnerability has been resolved:

drm/dp_mst: Handle torn-down topology gracefully in drm_dp_mst_topology_queue_probe()

A hotplug or link-loss event can tear down the MST topology
(setting mgr->mst_state = false and mgr->mst_primary = NULL) concurrently
with a caller invoking drm_dp_mst_topology_queue_probe(). Since the check
is already performed under mgr->lock, the condition is not a programming
error but a valid race -- the topology was valid when the caller decided
to call this function, but was torn down before the lock was acquired.

Replace the drm_WARN_ON() with a graceful early return. This eliminates
spurious kernel warnings and the resulting compositor crashes observed
when connecting/disconnecting DP MST monitors, while keeping the correct
behavior of doing nothing when MST is not active. A drm_dbg_mst() trace
is added so the skipped probe remains observable under MST debug logging.

The existing WARN_ON(mgr->mst_primary) in drm_dp_mst_topology_mgr_set_mst()
already catches the case where the topology is initialized twice, so no
diagnostic coverage is lost.

Comment 1 Mauro Matteo Cascella 2026-08-12 15:56:29 UTC
Upstream advisory:
https://lore.kernel.org/linux-cve-announce/2026081251-CVE-2026-68429-d0b9@gregkh/T