Bug 2527860 (CVE-2026-80754)

Summary: CVE-2026-80754 kernel: Input: synaptics-rmi4 - fix F55 transmitter electrode count typo
Product: [Other] Security Response Reporter: OSIDB Bzimport <bzimport>
Component: vulnerabilityAssignee: Product Security DevOps Team <prodsec-dev>
Status: NEW --- QA Contact:
Severity: medium Docs Contact:
Priority: medium    
Version: unspecifiedCC: akhatavk, aos-team-art-private, asdas, dpaolell, jdelft, jupierce, lgarciaa, mbiarnes, ppalepu, ppostler, prdhamdh, rhel-process-autobot, sghai, sidsharm, suppawar, vlaad, watson-tool-maintainers
Target Milestone: ---Keywords: Security
Target Release: ---   
Hardware: All   
OS: Linux   
Whiteboard:
Fixed In Version: Doc Type: ---
Doc Text:
A flaw was found in the Linux kernel's Synaptics RMI4 driver. During F55 sensor detection, a copy-paste error caused the transmitter (TX) electrode count to be incorrectly assigned the receiver (RX) electrode count. This miscalculation can lead to incorrect diagnostics report sizes and potential out-of-bounds buffer accesses. This could allow a local attacker to cause a denial of service or potentially execute arbitrary code.
Story Points: ---
Clone Of: Environment:
Last Closed: Type: ---
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:

Description OSIDB Bzimport 2026-09-03 08:42:24 UTC
In the Linux kernel, the following vulnerability has been resolved:

Input: synaptics-rmi4 - fix F55 transmitter electrode count typo

During F55 sensor detection, the transmitter (TX) electrode count was
incorrectly assigned the value of the receiver (RX) electrode count
due to copy-paste typos.

This incorrect value was then propagated to the driver data and used
by F54 to determine the diagnostics report size. On devices with more
RX than TX electrodes, this inflated the perceived TX count, leading
to incorrect report size calculations and potential out-of-bounds
buffer accesses.