Bug 2532501 (CVE-2026-89453)
| Summary: | CVE-2026-89453 kernel: iommu/amd: Put PCI device after handling PPR faults | ||
|---|---|---|---|
| Product: | [Other] Security Response | Reporter: | OSIDB Bzimport <bzimport> |
| Component: | vulnerability | Assignee: | Product Security <prodsec-ir-bot> |
| Status: | NEW --- | QA Contact: | |
| Severity: | low | Docs Contact: | |
| Priority: | low | ||
| Version: | unspecified | CC: | akhatavk, aos-team-art-private, asdas, dpaolell, jdelft, jupierce, lgarciaa, mbiarnes, ppalepu, ppostler, prdhamdh, rhel-process-autobot, sghai, sidsharm, suppawar, vlaad, watson-tool-maintainers |
| Target Milestone: | --- | Keywords: | Security |
| Target Release: | --- | ||
| Hardware: | All | ||
| OS: | Linux | ||
| Whiteboard: | |||
| Fixed In Version: | Doc Type: | --- | |
| Doc Text: |
A flaw was found in the Linux kernel's IOMMU (Input/Output Memory Management Unit) driver for AMD. This vulnerability occurs when the system handles certain memory access errors, specifically Page Request (PPR) faults, without properly releasing a reference to a PCI device. This oversight causes a resource leak, where system resources are not freed as expected. Over time, this could lead to resource exhaustion, potentially allowing a local attacker to cause a denial of service (DoS) on the system.
|
Story Points: | --- |
| Clone Of: | Environment: | ||
| Last Closed: | Type: | --- | |
| Regression: | --- | Mount Type: | --- |
| Documentation: | --- | CRM: | |
| Verified Versions: | Category: | --- | |
| oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
| Cloudforms Team: | --- | Target Upstream Version: | |
| Embargoed: | |||
In the Linux kernel, the following vulnerability has been resolved: iommu/amd: Put PCI device after handling PPR faults iommu_call_iopf_notifier() looks up the requester with pci_get_domain_bus_and_slot(), which returns a PCI device with its reference count incremented. Neither the successful iommu_report_device_fault() path nor the abort path drops that reference, so every handled PPR request leaks a PCI device reference. This is the same ownership rule that was fixed for the old iommu_v2 ppr_notifier() path by commit 6cf0981c2233 ("iommu/amd: Fix pci device refcount leak in ppr_notifier()"), but iommu_call_iopf_notifier() was added later as a separate PPR/IOPF notifier path. Drop the PCI device reference after handling the PPR entry.