Bug 2536590 (CVE-2026-90100)

Summary: CVE-2026-90100 kernel: ptp: netc: fix period truncation and potential divide-by-zero in PEROUT
Product: [Other] Security Response Reporter: OSIDB Bzimport <bzimport>
Component: vulnerabilityAssignee: Product Security <prodsec-ir-bot>
Status: NEW --- QA Contact:
Severity: medium Docs Contact:
Priority: medium    
Version: unspecifiedCC: akhatavk, aos-team-art-private, asdas, dpaolell, jdelft, jupierce, lgarciaa, mbiarnes, ppalepu, ppostler, prdhamdh, rhel-process-autobot, sghai, sidsharm, suppawar, vlaad, watson-tool-maintainers
Target Milestone: ---Keywords: Security
Target Release: ---   
Hardware: All   
OS: Linux   
Whiteboard:
Fixed In Version: Doc Type: ---
Doc Text:
A flaw was found in the Linux kernel's Precision Time Protocol (PTP) netc driver. An issue with period calculation can lead to a value being truncated to zero. This truncated value can then cause a divide-by-zero error in the `netc_timer_set_perout_alarm()` function, resulting in a system crash and a Denial of Service (DoS). Additionally, a zero period can lead to incorrect hardware register programming.
Story Points: ---
Clone Of: Environment:
Last Closed: Type: ---
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:

Description OSIDB Bzimport 2026-09-17 18:36:12 UTC
In the Linux kernel, the following vulnerability has been resolved:

ptp: netc: fix period truncation and potential divide-by-zero in PEROUT

The max_period bound in net_timer_enable_perout() was computed as:

  max_period = (u64)NETC_TMR_DEFAULT_FIPER + integral_period;

which exceeds U32_MAX when integral_period > 0 (e.g. 0x100000002 for
the default 333333333 Hz clock). A period_ns that passes this check but
exceeds U32_MAX is then silently truncated when stored into the u32
struct netc_pp::period field.

A truncated value of zero can reach netc_timer_set_perout_alarm(), where
the local u32 period variable would also be 0, causing a divide-by-zero
in roundup_u64(delta, period) whenever the stime < min_time branch is
taken (which always happens for a start time of {0, 0}).

Additionally, netc_timer_enable_periodic_pulse() and
netc_timer_enable_fiper() both compute:

  fiper = pp->period - integral_period;

A zero pp->period results in an unsigned wraparound to 0xFFFFFFFD,
mis-programming the FIPER hardware register.

Fix all three issues by capping max_period at NETC_TMR_DEFAULT_FIPER
(0xFFFFFFFF). This ensures that any period_ns passing the range check
fits in a u32 without truncation, so the stored value is always valid
and non-zero. The accepted range is reduced by integral_period ns
(typically only a few nanoseconds), which is negligible in practice.