Bug 2555152 (CVE-2026-98676)

Summary: CVE-2026-98676 kernel: iio: adc: ade9000: fix NULL pointer dereference in clkout registration
Product: [Other] Security Response Reporter: OSIDB Bzimport <bzimport>
Component: vulnerabilityAssignee: Product Security DevOps Team <prodsec-dev>
Status: NEW --- QA Contact:
Severity: medium Docs Contact:
Priority: medium    
Version: unspecifiedCC: akhatavk, aos-team-art-private, asdas, dpaolell, jdelft, jupierce, lgarciaa, mbiarnes, ppalepu, ppostler, prdhamdh, rhel-process-autobot, sghai, sidsharm, suppawar, vlaad, watson-tool-maintainers
Target Milestone: ---Keywords: Security
Target Release: ---   
Hardware: All   
OS: Linux   
Whiteboard:
Fixed In Version: Doc Type: ---
Doc Text:
A flaw was found in the Linux kernel's ADE9000 driver. This vulnerability allows a local user to cause a denial of service (DoS) and system crash when probing an ADE9000 device configured as a clock provider with an external input clock. During clock output registration, the driver supplies an invalid null memory address, triggering a NULL pointer dereference when the kernel attempts to calculate clock rates.
Story Points: ---
Clone Of: Environment:
Last Closed: Type: ---
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:

Description OSIDB Bzimport 2026-10-18 15:57:22 UTC
In the Linux kernel, the following vulnerability has been resolved:

iio: adc: ade9000: fix NULL pointer dereference in clkout registration

ade9000_setup_clkout() passes NULL as the register address when
registering a divider clock. During clock registration, the common
clock framework calls clk_divider_recalc_rate(), which dereferences
the address through readl(). As a result, probing an ADE9000 configured
as a clock provider with an external input clock crashes.

CLKOUT passes CLKIN through without changing its rate. Register it as
a 1:1 fixed-factor clock, which does not require register access.

This change does not affect the configuration using the internal clock,
for which the driver does not register a clock provider.