Bug 2576936 (CVE-2026-99445)
| Summary: | CVE-2026-99445 kernel: kernel: Denial of Service via use-after-free in PF1550 charger driver | ||
|---|---|---|---|
| Product: | [Other] Security Response | Reporter: | OSIDB Bzimport <bzimport> |
| Component: | vulnerability | Assignee: | Product Security DevOps Team <prodsec-dev> |
| Status: | NEW --- | QA Contact: | |
| Severity: | medium | Docs Contact: | |
| Priority: | medium | ||
| Version: | unspecified | CC: | akhatavk, aos-team-art-private, asdas, dpaolell, jdelft, jupierce, lgarciaa, mbiarnes, ppalepu, ppostler, prdhamdh, rhel-process-autobot, sghai, sidsharm, suppawar, vlaad, watson-tool-maintainers |
| Target Milestone: | --- | Keywords: | Security |
| Target Release: | --- | ||
| Hardware: | All | ||
| OS: | Linux | ||
| Whiteboard: | |||
| Fixed In Version: | Doc Type: | --- | |
| Doc Text: |
A flaw was found in the Linux kernel's PF1550 battery charger driver. This vulnerability can lead to a Denial of Service (DoS) through a system crash. During device teardown or driver unbinding, power supply resources may be released while interrupt-triggered background tasks are still pending. A local privileged user able to trigger device cleanup could cause these queued tasks to access freed memory, resulting in a use-after-free condition.
|
Story Points: | --- |
| Clone Of: | Environment: | ||
| Last Closed: | Type: | --- | |
| Regression: | --- | Mount Type: | --- |
| Documentation: | --- | CRM: | |
| Verified Versions: | Category: | --- | |
| oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
| Cloudforms Team: | --- | Target Upstream Version: | |
| Embargoed: | |||
In the Linux kernel, the following vulnerability has been resolved: power: supply: pf1550: drain IRQ work before unregistering supplies The VBUS work calls power_supply_changed(), but its managed cancellation is registered before the supplies. Cleanup can therefore unregister a supply while IRQ-triggered work is still pending. Commit 838767f50747 ("power: supply: pf1550: Fix use-after-free in power_supply_changed()") moved IRQ requests after supply registration, but left work cancellation before the supplies. That change protects the direct IRQ callbacks, while this fix drains the work they queue. Register the three work items after both supplies and before the IRQs. Cleanup then frees the IRQ producers, drains the work, and unregisters the supplies. The teardown ordering issue was found by static analysis.