Bug 517965
Summary: | MegaRAID SAS 1078 tape I/O errors when using mt erase [rhel-4.8.z] | ||
---|---|---|---|
Product: | Red Hat Enterprise Linux 4 | Reporter: | RHEL Program Management <pm-rhel> |
Component: | kernel | Assignee: | Vitaly Mayatskikh <vmayatsk> |
Status: | CLOSED ERRATA | QA Contact: | Red Hat Kernel QE team <kernel-qe> |
Severity: | urgent | Docs Contact: | |
Priority: | urgent | ||
Version: | 4.8 | CC: | coughlan, pm-eus |
Target Milestone: | rc | Keywords: | ZStream |
Target Release: | --- | ||
Hardware: | All | ||
OS: | Linux | ||
Whiteboard: | |||
Fixed In Version: | Doc Type: | Bug Fix | |
Doc Text: |
Time-outs resulted in I/O errors being logged to "/var/log/messages" when running "mt erase" on tape drives using certain LSI MegaRAID SAS adapters, preventing the command from completing. The megaraid_sas driver's timeout value is now set to the OS layer value.
|
Story Points: | --- |
Clone Of: | Environment: | ||
Last Closed: | 2009-09-15 08:31:18 UTC | Type: | --- |
Regression: | --- | Mount Type: | --- |
Documentation: | --- | CRM: | |
Verified Versions: | Category: | --- | |
oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
Cloudforms Team: | --- | Target Upstream Version: | |
Embargoed: | |||
Bug Depends On: | 504080 | ||
Bug Blocks: |
Description
RHEL Program Management
2009-08-18 08:16:59 UTC
Committed in 89.0.11 An advisory has been issued which should help the problem described in this bug report. This report is therefore being closed with a resolution of ERRATA. For more information on therefore solution and/or where to find the updated files, please follow the link below. You may reopen this bug report if the solution does not work for you. http://rhn.redhat.com/errata/RHSA-2009-1438.html Technical note added. If any revisions are required, please edit the "Technical Notes" field accordingly. All revisions will be proofread by the Engineering Content Services team. New Contents: Time-outs resulted in I/O errors being logged to "/var/log/messages" when running "mt erase" on tape drives using certain LSI MegaRAID SAS adapters, preventing the command from completing. The megaraid_sas driver's timeout value is now set to the OS layer value. |