Bug 641456

Summary: [Intel 6.1 Bug] FCoE Boot ROM, unable to see LUN during system install thru NPV [rhel-6.0.z]
Product: Red Hat Enterprise Linux 6 Reporter: Benjamin Kahn <bkahn>
Component: kernelAssignee: Frantisek Hrbata <fhrbata>
Status: CLOSED ERRATA QA Contact: Storage QE <storage-qe>
Severity: high Docs Contact:
Priority: urgent    
Version: 6.0CC: arozansk, bdonahue, borgan, coughlan, cward, dhoward, jack.morgan, jane.lv, john.ronciak, jpirko, jvillalo, kzhang, luyu, mchristi, pm-eus, robert.w.love, rpacheco, syeghiay
Target Milestone: rcKeywords: OtherQA, ZStream
Target Release: 6.1   
Hardware: All   
OS: Linux   
Whiteboard:
Fixed In Version: kernel-2.6.32-71.4.1.el6 Doc Type: Bug Fix
Doc Text:
During an installation through Cisco NPV (N port virtualization) to Brocade, adding a LUN (Logical Unit Number) through Add Advanced Target did not work properly. This was caused by the faulty resending of FLOGI (Fabric Login) when a Fibre Channel switch in the NPV mode rejected requests with zero Destination ID. With this update, the LUN is seen and able to be selected for installation.
Story Points: ---
Clone Of: Environment:
Last Closed: 2010-11-10 19:10:57 UTC Type: ---
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:
Bug Depends On: 633907    
Bug Blocks:    

Description Benjamin Kahn 2010-10-08 18:56:38 UTC
This bug has been copied from bug #633907 and has been proposed
to be backported to 6.0 z-stream (EUS).

Comment 2 Frantisek Hrbata 2010-10-12 18:53:21 UTC
in kernel-2.6.32-71.4.1.el6

Comment 6 Jack Morgan 2010-10-27 00:53:25 UTC
Verified fixed by Intel

Comment 8 errata-xmlrpc 2010-11-10 19:10:57 UTC
An advisory has been issued which should help the problem
described in this bug report. This report is therefore being
closed with a resolution of ERRATA. For more information
on therefore solution and/or where to find the updated files,
please follow the link below. You may reopen this bug report
if the solution does not work for you.

http://rhn.redhat.com/errata/RHSA-2010-0842.html

Comment 9 Martin Prpič 2010-11-11 12:01:09 UTC
    Technical note added. If any revisions are required, please edit the "Technical Notes" field
    accordingly. All revisions will be proofread by the Engineering Content Services team.
    
    New Contents:
During an installation through Cisco NPV (N port virtualization) to Brocade, adding a LUN (Logical Unit Number) through Add Advanced Target did not work properly. This was caused by the faulty resending of FLOGI (Fabric Login) when a Fibre Channel switch in the NPV mode rejected requests with zero Destination ID. With this update, the LUN is seen and able to be selected for installation.