Bug 641456
Summary: | [Intel 6.1 Bug] FCoE Boot ROM, unable to see LUN during system install thru NPV [rhel-6.0.z] | ||
---|---|---|---|
Product: | Red Hat Enterprise Linux 6 | Reporter: | Benjamin Kahn <bkahn> |
Component: | kernel | Assignee: | Frantisek Hrbata <fhrbata> |
Status: | CLOSED ERRATA | QA Contact: | Storage QE <storage-qe> |
Severity: | high | Docs Contact: | |
Priority: | urgent | ||
Version: | 6.0 | CC: | arozansk, bdonahue, borgan, coughlan, cward, dhoward, jack.morgan, jane.lv, john.ronciak, jpirko, jvillalo, kzhang, luyu, mchristi, pm-eus, robert.w.love, rpacheco, syeghiay |
Target Milestone: | rc | Keywords: | OtherQA, ZStream |
Target Release: | 6.1 | ||
Hardware: | All | ||
OS: | Linux | ||
Whiteboard: | |||
Fixed In Version: | kernel-2.6.32-71.4.1.el6 | Doc Type: | Bug Fix |
Doc Text: |
During an installation through Cisco NPV (N port virtualization) to Brocade, adding a LUN (Logical Unit Number) through Add Advanced Target did not work properly. This was caused by the faulty resending of FLOGI (Fabric Login) when a Fibre Channel switch in the NPV mode rejected requests with zero Destination ID. With this update, the LUN is seen and able to be selected for installation.
|
Story Points: | --- |
Clone Of: | Environment: | ||
Last Closed: | 2010-11-10 19:10:57 UTC | Type: | --- |
Regression: | --- | Mount Type: | --- |
Documentation: | --- | CRM: | |
Verified Versions: | Category: | --- | |
oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
Cloudforms Team: | --- | Target Upstream Version: | |
Embargoed: | |||
Bug Depends On: | 633907 | ||
Bug Blocks: |
Description
Benjamin Kahn
2010-10-08 18:56:38 UTC
in kernel-2.6.32-71.4.1.el6 Verified fixed by Intel An advisory has been issued which should help the problem described in this bug report. This report is therefore being closed with a resolution of ERRATA. For more information on therefore solution and/or where to find the updated files, please follow the link below. You may reopen this bug report if the solution does not work for you. http://rhn.redhat.com/errata/RHSA-2010-0842.html Technical note added. If any revisions are required, please edit the "Technical Notes" field accordingly. All revisions will be proofread by the Engineering Content Services team. New Contents: During an installation through Cisco NPV (N port virtualization) to Brocade, adding a LUN (Logical Unit Number) through Add Advanced Target did not work properly. This was caused by the faulty resending of FLOGI (Fabric Login) when a Fibre Channel switch in the NPV mode rejected requests with zero Destination ID. With this update, the LUN is seen and able to be selected for installation. |