Bug 642915
| Summary: | wacom control panel functions are not working | |||
|---|---|---|---|---|
| Product: | Red Hat Enterprise Linux 6 | Reporter: | RHEL Program Management <pm-rhel> | |
| Component: | wacomcpl | Assignee: | Peter Hutterer <peter.hutterer> | |
| Status: | CLOSED ERRATA | QA Contact: | desktop-bugs <desktop-bugs> | |
| Severity: | urgent | Docs Contact: | ||
| Priority: | urgent | |||
| Version: | 6.0 | CC: | borgan, cmeadors, cww, ddumas, jlaska, mboisver, peter.hutterer, pm-eus, spurrier, syeghiay, tao, vbenes, vsharapo | |
| Target Milestone: | rc | Keywords: | RHELNAK, ZStream | |
| Target Release: | --- | |||
| Hardware: | All | |||
| OS: | Linux | |||
| Whiteboard: | ||||
| Fixed In Version: | wacomcpl-0.9.0-1.el6.2, xorg-x11-drv-wacom-0.10.5-6.el6.2 | Doc Type: | Bug Fix | |
| Doc Text: |
Prior to this update, changing the screen mapping may have caused the wacompl graphical user interface to stop responding. Additionally, an attempt to calibrate a device may have failed with an error message. With this update, the underlying source code has been modified to target these issues.
|
Story Points: | --- | |
| Clone Of: | ||||
| : | 681710 (view as bug list) | Environment: | ||
| Last Closed: | 2011-03-10 09:12:04 UTC | Type: | --- | |
| Regression: | --- | Mount Type: | --- | |
| Documentation: | --- | CRM: | ||
| Verified Versions: | Category: | --- | ||
| oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | ||
| Cloudforms Team: | --- | Target Upstream Version: | ||
| Embargoed: | ||||
| Bug Depends On: | 624560 | |||
| Bug Blocks: | ||||
|
Description
RHEL Program Management
2010-10-14 06:59:08 UTC
MODIFIED xorg-x11-drv-wacom-0.10.5-6.el6.1 and wacomcpl-0.9.0-1.el6.1 are available in brew. Hi Scott, could you please retest for us in rhel6 and tell if those functions satisfies your needs now? We have an erratum now so new packages are available in brew. Thanks, Vladimir
Technical note added. If any revisions are required, please edit the "Technical Notes" field
accordingly. All revisions will be proofread by the Engineering Content Services team.
New Contents:
Prior to this update, changing the screen mapping may have caused the wacompl graphical user interface to stop responding. Additionally, an attempt to calibrate a device may have failed with an error message. With this update, the underlying source code has been modified to target these issues.
I noticed the status of assigned and the new packages. Is this fix ready to be tested? I have the hardware already set up and ready. Michael, I am still waiting for the customer to confirm that this set addresses all issues. If you can confirm the same, that'd be much appreciated. I can confirm that from basic testing, it appears that the 3 problems outlined in the previous bug have been fixed. I was able to use twinview and calibrate it onto one screen of the Cintiq 21UX, and assign tool buttons that saved. MODIFIED wacomcpl-0.9.0-1.el6_0.2 and xorg-x11-drv-wacom-0.10.5-6.el6_0.2 are available in brew. The tool buttons issue is actually still there, just more subtle. Here is how to reproduce: 1. Map Button 1 on the pad to "CTRL z" - In .wacomcplrc it's now "core key CTRL z" - Button 1 works as expected. 2. Re-open Tool Buttons, notice that Button1 shows up as "Keystroke" as it should, map Button 2 on the pad to "CTRL y", save. - In .wacomcplrc Button 2 is now "core key CTRL y" - In .wacomcplrc Button 1 is now "" - Button 2 works but Button 1 does nothing. It seems wacomcpl isn't saving the custom options it's loaded from its own configuration. Tell us if you need any info Peter. Hi Peter, could you please provide an update about the issue Vasiliy outlined above? (In reply to comment #24) > It seems wacomcpl isn't saving the custom options it's loaded from its own > configuration. urgh. yes, verified. this is a bigger issue. Can you please file a separate bug for this? thanks. Bug tested in RHEL6.0.z with wacomcpl-0.9.0-1.el6_0.2 and xorg-x11-drv-wacom-0.10.5-6.el6_0.2, 32bit and 64bit versions. Screen mapping is now working properly in TwinView. Calibration is accurate when used in TwinView or not. Tool button assignment seems to be working properly now. I was seeing an issue with too button assignment a few days ago, but I have been unable to reproduce the error since. There is a new bug created for a slightly different issue, so I am going to verify this bug. An advisory has been issued which should help the problem described in this bug report. This report is therefore being closed with a resolution of ERRATA. For more information on therefore solution and/or where to find the updated files, please follow the link below. You may reopen this bug report if the solution does not work for you. http://rhn.redhat.com/errata/RHBA-2011-0341.html |