Bug 646817

Summary: System health indicator in "Systems" related pages not displayed
Product: Red Hat Satellite 5 Reporter: Garik Khachikyan <gkhachik>
Component: MonitoringAssignee: Lukas Zapletal <lzap>
Status: CLOSED ERRATA QA Contact: Garik Khachikyan <gkhachik>
Severity: high Docs Contact:
Priority: high    
Version: 540CC: lzap, mkoci
Target Milestone: ---Keywords: Regression
Target Release: ---   
Hardware: Unspecified   
OS: Unspecified   
Whiteboard:
Fixed In Version: spacewalk-java-1.2.39-30 Doc Type: Bug Fix
Doc Text:
The monitoring status icon is now properly displayed.
Story Points: ---
Clone Of:
: 656311 (view as bug list) Environment:
Last Closed: 2010-12-16 15:44:30 UTC Type: ---
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:
Bug Depends On:    
Bug Blocks: 646488, 656311    

Description Garik Khachikyan 2010-10-26 11:24:30 UTC
Description of problem:
For the systems that have Monitoring probes assigned, the "health" icon indicating the state of systems is not shown.
For example the pages:
---
https://<sat>/rhn/systems/Overview.do
https://<sat>/rhn/systems/SystemList.do
https://<sat>/rhn/systems/Ungrouped.do
... and similar.
---

Version-Release number of selected component (if applicable):
Current sat 540 with stage-signed iso/packages.

How reproducible:
always when monitoring is enabled and system(s) have probes assigned.

Steps to Reproduce:
1. have satellite with Monitoring enabled (+Scout - not sure if important, but anyway)
2. register a system, entitle appropriately for Monitoring 
3. make a monitoring probe
  
Actual results:
No icon appears indicating that system is under monitoring control.

Expected results:
The icon appears, later on if all the settings configured well - should get probe results.

Additional info:
For Satellite 530 it's working~

Comment 2 Garik Khachikyan 2010-10-26 11:27:51 UTC
btw: in the page of system groups the indicator is available.

Comment 5 Lukas Zapletal 2010-11-24 10:38:36 UTC
commit 6f4fcd1bf9c785cbffdc0bb76a8cdf8dfb39d8e7
Author: Lukas Zapletal <lzap+git>
Date:   Tue Nov 23 14:08:44 2010 +0100

    646817 - System health indicator in "Systems" related pages not displayed
    
    Adding missing ">" bracket.
    
    (cherry picked from commit c36b7847e118239af21ef284160693308e1db91b)

Comment 6 Lukas Zapletal 2010-11-26 09:24:59 UTC
Please note:

This error does occur on Webkit browsers (and maybe others). The workaroud is to use Firefox.

Comment 9 Garik Khachikyan 2010-12-10 16:06:51 UTC
# VERIFIED

following are the packages fixing the issue:
---
spacewalk-java-1.2.39-34.el5sat
spacewalk-java-oracle-1.2.39-34.el5sat
spacewalk-java-config-1.2.39-34.el5sat
spacewalk-java-lib-1.2.39-34.el5sat
spacewalk-taskomatic-1.2.39-34.el5sat
---

checked on FF, Opera, Google Chrome - all are displaying the probe health status properly now.

Comment 11 errata-xmlrpc 2010-12-16 15:44:30 UTC
An advisory has been issued which should help the problem
described in this bug report. This report is therefore being
closed with a resolution of ERRATA. For more information
on therefore solution and/or where to find the updated files,
please follow the link below. You may reopen this bug report
if the solution does not work for you.

http://rhn.redhat.com/errata/RHBA-2010-0991.html

Comment 12 Jaromir Hradilek 2010-12-16 16:34:46 UTC
    Technical note added. If any revisions are required, please edit the "Technical Notes" field
    accordingly. All revisions will be proofread by the Engineering Content Services team.
    
    New Contents:
The monitoring status icon is now properly displayed.