Bug 657297

Summary: [abrt] crash in bacula-traymonitor-3.0.3-5.fc12: __strlen_sse2: Process /usr/sbin/bacula-tray-monitor was killed by signal 11 (SIGSEGV)
Product: Red Hat Enterprise Linux 6 Reporter: Jan Görig <jgorig>
Component: baculaAssignee: Jan Görig <jgorig>
Status: CLOSED ERRATA QA Contact: qe-baseos-daemons
Severity: medium Docs Contact:
Priority: low    
Version: 6.1CC: adam, andreas, azelinka, dnovotny, fschwarz, gwync, jgorig, mmcgrath, ovasik, pkovar, rvokal, tbeattie, trevin, vanmeeuwen+fedora
Target Milestone: rc   
Target Release: ---   
Hardware: i686   
OS: Linux   
Whiteboard: abrt_hash:afc9288dd6bae7b381f1f1fedc3df969a50d5206
Fixed In Version: bacula-5.0.0-8.el6 Doc Type: Bug Fix
Doc Text:
Prior to this update, Bacula's default configuration missed a required option. As a result, the Bacula tray monitor component terminated unexpectedly. The problem has been fixed by adding the "Address" option to the "Director" section in the Bacula tray monitor configuration file so that the Bacula tray monitor now works as expected with the default configuration file. Note that this bug fix does not alter any existing Bacula tray monitor configuration file. As a consequence, the Bacula tray monitor can terminate unexpectedly if the existing Bacula tray monitor configuration is incorrect.
Story Points: ---
Clone Of: 626490 Environment:
Last Closed: 2011-08-31 09:17:06 UTC Type: ---
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:
Bug Depends On: 626490    
Bug Blocks:    

Comment 3 Suzanne Logcher 2011-02-15 21:45:32 UTC
This issue was proposed for RHEL 6.1 FasTrack but did not get resolved in time.
It has been moved to RHEL 6.2 FasTrack.

Comment 7 Jan Görig 2011-06-08 14:59:24 UTC
    Technical note added. If any revisions are required, please edit the "Technical Notes" field
    accordingly. All revisions will be proofread by the Engineering Content Services team.
    
    New Contents:
Cause
 - missing required option in default config
Consequence
 - bacula tray monitor was crashing immediately 
Fix
 - added 'Address' option to tray monitor config file
Result
 - tray monitor is not crashing with default config file

Comment 8 Jan Görig 2011-06-08 15:16:45 UTC
    Technical note updated. If any revisions are required, please edit the "Technical Notes" field
    accordingly. All revisions will be proofread by the Engineering Content Services team.
    
    Diffed Contents:
@@ -3,6 +3,6 @@
 Consequence
  - bacula tray monitor was crashing immediately 
 Fix
- - added 'Address' option to tray monitor config file
+ - added 'Address' option in 'Director' section to tray monitor config file
 Result
  - tray monitor is not crashing with default config file

Comment 10 Jan Görig 2011-06-09 07:39:59 UTC
    Technical note updated. If any revisions are required, please edit the "Technical Notes" field
    accordingly. All revisions will be proofread by the Engineering Content Services team.
    
    Diffed Contents:
@@ -5,4 +5,5 @@
 Fix
  - added 'Address' option in 'Director' section to tray monitor config file
 Result
- - tray monitor is not crashing with default config file+ - tray monitor is not crashing with default config file 
+(this change doesn't alter existing config so tray monitor will crash with existing incorrect configuration)

Comment 11 Petr Kovar 2011-06-15 16:07:09 UTC
    Technical note updated. If any revisions are required, please edit the "Technical Notes" field
    accordingly. All revisions will be proofread by the Engineering Content Services team.
    
    Diffed Contents:
@@ -1,9 +1 @@
-Cause
+Prior to this update, Bacula's default configuration missed a required option. As a result, the Bacula tray monitor component terminated unexpectedly. The problem has been fixed by adding the "Address" option to the "Director" section in the Bacula tray monitor configuration file so that the Bacula tray monitor now works as expected with the default configuration file. Note that this bug fix does not alter any existing Bacula tray monitor configuration file. As a consequence, the Bacula tray monitor can terminate unexpectedly if the existing Bacula tray monitor configuration is incorrect.- - missing required option in default config
-Consequence
- - bacula tray monitor was crashing immediately 
-Fix
- - added 'Address' option in 'Director' section to tray monitor config file
-Result
- - tray monitor is not crashing with default config file 
-(this change doesn't alter existing config so tray monitor will crash with existing incorrect configuration)

Comment 14 errata-xmlrpc 2011-08-31 09:17:06 UTC
An advisory has been issued which should help the problem
described in this bug report. This report is therefore being
closed with a resolution of ERRATA. For more information
on therefore solution and/or where to find the updated files,
please follow the link below. You may reopen this bug report
if the solution does not work for you.

http://rhn.redhat.com/errata/RHBA-2011-1232.html