Bug 675672

Summary: wacomcpl calibration slightly off with twiview set up to "leftOf"
Product: Red Hat Enterprise Linux 6 Reporter: Olivier Fourdan <ofourdan>
Component: wacomcplAssignee: Peter Hutterer <peter.hutterer>
Status: CLOSED ERRATA QA Contact: Desktop QE <desktop-qa-list>
Severity: medium Docs Contact:
Priority: medium    
Version: 6.0CC: kem, mboisver, spurrier, tpelka
Target Milestone: rc   
Target Release: ---   
Hardware: Unspecified   
OS: Unspecified   
Whiteboard:
Fixed In Version: xorg-x11-drv-wacom-0.10.5-11.el6, wacomcpl-0.10.0-2.el6 Doc Type: Bug Fix
Doc Text:
Previously, calibration could be inaccurate when using TwinView while the orientation was set to "LeftOf". With this update, the source code is modified and calibration now works as expected.
Story Points: ---
Clone Of: Environment:
Last Closed: 2011-12-06 12:12:05 UTC Type: ---
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:
Bug Depends On:    
Bug Blocks: 658636, 697582, 713024    
Attachments:
Description Flags
Disney Patches none

Comment 2 Scott Spurrier 2011-02-24 23:42:18 UTC
Created attachment 480890 [details]
Disney Patches

Comment 18 Peter Hutterer 2011-07-01 01:57:08 UTC
    Technical note added. If any revisions are required, please edit the "Technical Notes" field
    accordingly. All revisions will be proofread by the Engineering Content Services team.
    
    New Contents:
Changes to the calibration code causes previously made calibrations to become obsolete. Users of wacomcpl or xorg-x11-drv-wacom need to re-calibrate the device when updating to the new packages.

Comment 19 Peter Hutterer 2011-07-06 05:40:01 UTC
MODIFIED

xorg-x11-drv-wacom-0.10.5-11.el6 and wacomcpl-0.10.0-2.el6 are available in brew

Comment 26 Michael Boisvert 2011-09-09 14:21:08 UTC
xorg-x11-drv-wacom-0.10.5-13.el6 and wacomcpl-0.10.0-3.el6 on RHEL6.2 using a Wacom DTU-2231 (21.5" 16:9 widescreen), calibration in "LeftOf" mode seems to be accurate. More testing will verify this. I will try with both 21UX and 21UX2.

Comment 33 Eliska Slobodova 2011-10-10 12:09:24 UTC
    Technical note updated. If any revisions are required, please edit the "Technical Notes" field
    accordingly. All revisions will be proofread by the Engineering Content Services team.
    
    Diffed Contents:
@@ -1 +1 @@
-Changes to the calibration code causes previously made calibrations to become obsolete. Users of wacomcpl or xorg-x11-drv-wacom need to re-calibrate the device when updating to the new packages.+Previously, calibration could be inaccurate when using TwinView while the orientation was set to "LeftOf". With this update, the source code is modified and calibration now works as expected.

Comment 34 errata-xmlrpc 2011-12-06 12:12:05 UTC
Since the problem described in this bug report should be
resolved in a recent advisory, it has been closed with a
resolution of ERRATA.

For information on the advisory, and where to find the updated
files, follow the link below.

If the solution does not work for you, open a new bug report.

http://rhn.redhat.com/errata/RHBA-2011-1588.html