Bug 693427
Summary: | fence_ipmilan returns incorrect status on monitor op if chassis is powered off | ||
---|---|---|---|
Product: | Red Hat Enterprise Linux 5 | Reporter: | Marek Grac <mgrac> |
Component: | cman | Assignee: | Marek Grac <mgrac> |
Status: | CLOSED ERRATA | QA Contact: | Cluster QE <mspqa-list> |
Severity: | high | Docs Contact: | |
Priority: | high | ||
Version: | 5.6 | CC: | bubble, cluster-maint, djansa, edamato, fdinitto |
Target Milestone: | rc | ||
Target Release: | --- | ||
Hardware: | Unspecified | ||
OS: | Unspecified | ||
Whiteboard: | |||
Fixed In Version: | cman-2.0.115-80.el5 | Doc Type: | Bug Fix |
Doc Text: | Story Points: | --- | |
Clone Of: | 690735 | Environment: | |
Last Closed: | 2011-07-21 07:26:25 UTC | Type: | --- |
Regression: | --- | Mount Type: | --- |
Documentation: | --- | CRM: | |
Verified Versions: | Category: | --- | |
oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
Cloudforms Team: | --- | Target Upstream Version: | |
Embargoed: | |||
Bug Depends On: | 690735, 693428 | ||
Bug Blocks: | 693426 |
Description
Marek Grac
2011-04-04 15:57:46 UTC
[root@marathon-04 ~]# fence_ipmilan -a z2-ipmi -l XXX -p XXX -o off Powering off machine @ IPMI:z2-ipmi...Done [root@marathon-04 ~]# fence_ipmilan -a z2-ipmi -l XXX -p XXX -o monitor Getting status of IPMI:z2-ipmi...Done [root@marathon-04 ~]# echo $? 0 verified in cman-2.0.115-82.el5 An advisory has been issued which should help the problem described in this bug report. This report is therefore being closed with a resolution of ERRATA. For more information on therefore solution and/or where to find the updated files, please follow the link below. You may reopen this bug report if the solution does not work for you. http://rhn.redhat.com/errata/RHBA-2011-1001.html |