| Summary: | non raid1 volumes are not able to be repaired after device failure | ||
|---|---|---|---|
| Product: | Red Hat Enterprise Linux 6 | Reporter: | Corey Marthaler <cmarthal> |
| Component: | lvm2 | Assignee: | Jonathan Earl Brassow <jbrassow> |
| Status: | CLOSED ERRATA | QA Contact: | Cluster QE <mspqa-list> |
| Severity: | high | Docs Contact: | |
| Priority: | high | ||
| Version: | 6.3 | CC: | agk, dwysocha, heinzm, jbrassow, mbroz, prajnoha, prockai, thornber, zkabelac |
| Target Milestone: | rc | ||
| Target Release: | --- | ||
| Hardware: | x86_64 | ||
| OS: | Linux | ||
| Whiteboard: | |||
| Fixed In Version: | lvm2-2.02.95-1.el6 | Doc Type: | Bug Fix |
| Doc Text: |
New Feature to 6.3. No documentation required.
Bug 732458 is the bug that requires a release note for the RAID features. Other documentation is found in the LVM manual.
Operational bugs need no documentation because they are being fixed before their initial release.
|
Story Points: | --- |
| Clone Of: | Environment: | ||
| Last Closed: | 2012-06-20 15:01:37 UTC | Type: | --- |
| Regression: | --- | Mount Type: | --- |
| Documentation: | --- | CRM: | |
| Verified Versions: | Category: | --- | |
| oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
| Cloudforms Team: | --- | Target Upstream Version: | |
|
Description
Corey Marthaler
2012-02-22 17:43:35 UTC
Fix checked in upstream in 2.02.93. I've confirmed the solution works with 'raid1' and 'raid5' for the "warn" and "allocate" policies. Fix verified in the latest rpms. 2.6.32-251.el6.x86_64 lvm2-2.02.95-2.el6 BUILT: Fri Mar 16 08:39:54 CDT 2012 lvm2-libs-2.02.95-2.el6 BUILT: Fri Mar 16 08:39:54 CDT 2012 lvm2-cluster-2.02.95-2.el6 BUILT: Fri Mar 16 08:39:54 CDT 2012 udev-147-2.40.el6 BUILT: Fri Sep 23 07:51:13 CDT 2011 device-mapper-1.02.74-2.el6 BUILT: Fri Mar 16 08:39:54 CDT 2012 device-mapper-libs-1.02.74-2.el6 BUILT: Fri Mar 16 08:39:54 CDT 2012 device-mapper-event-1.02.74-2.el6 BUILT: Fri Mar 16 08:39:54 CDT 2012 device-mapper-event-libs-1.02.74-2.el6 BUILT: Fri Mar 16 08:39:54 CDT 2012 cmirror-2.02.95-2.el6 BUILT: Fri Mar 16 08:39:54 CDT 2012 [...] Fault policy is warn, manually repairing failed raid volumes taft-01: 'echo y | lvconvert --repair black_bird/synced_random_raid6_4legs_1' /dev/sde1: read failed after 0 of 512 at 145669554176: Input/output error /dev/sde1: read failed after 0 of 512 at 145669664768: Input/output error /dev/sde1: read failed after 0 of 512 at 0: Input/output error /dev/sde1: read failed after 0 of 512 at 4096: Input/output error /dev/sde1: read failed after 0 of 2048 at 0: Input/output error Couldn't find device with uuid DVXjHM-T5RK-34Uj-g103-OHy7-0Bg2-SKZd7g. Attempt to replace failed RAID images (requires full device resync)? [y/n]: Waiting until all mirror|raid volumes become fully syncd... 1/1 mirror(s) are fully synced: ( 100.00% ) [...]
Technical note added. If any revisions are required, please edit the "Technical Notes" field
accordingly. All revisions will be proofread by the Engineering Content Services team.
New Contents:
New Feature to 6.3. No documentation required.
Bug 732458 is the bug that requires a release note for the RAID features. Other documentation is found in the LVM manual.
Operational bugs need no documentation because they are being fixed before their initial release.
Since the problem described in this bug report should be resolved in a recent advisory, it has been closed with a resolution of ERRATA. For information on the advisory, and where to find the updated files, follow the link below. If the solution does not work for you, open a new bug report. http://rhn.redhat.com/errata/RHBA-2012-0962.html |