Bug 969005
Summary: | openhpi 2.14.x segfaults when retrieving thermal info | ||
---|---|---|---|
Product: | Red Hat Enterprise Linux 6 | Reporter: | Libor Miksik <lmiksik> |
Component: | openhpi | Assignee: | Dan HorĂ¡k <dhorak> |
Status: | CLOSED ERRATA | QA Contact: | Juraj Marko <jmarko> |
Severity: | high | Docs Contact: | |
Priority: | urgent | ||
Version: | 6.3 | CC: | azelinka, dhorak, jskala, michele, mkolaja, nlevinki, ovasik, pm-eus |
Target Milestone: | rc | Keywords: | EasyFix, Patch, Upstream, ZStream |
Target Release: | --- | ||
Hardware: | All | ||
OS: | Linux | ||
Whiteboard: | |||
Fixed In Version: | openhpi-2.14.1-3.el6_4.3 | Doc Type: | Bug Fix |
Doc Text: |
Cause:
If any of the following HP blades are present in an enclosure, openhpi will segfault at startup:
HP BL465C G7
HP BL480CG1
HP BL685CG6
Consequence:
Segfault during startup
Fix:
A patch adding support for these blades and their sensors has been added.
Result:
Openhpi will not segfault in presence of the above blades
|
Story Points: | --- |
Clone Of: | Environment: | ||
Last Closed: | 2013-07-08 09:51:02 UTC | Type: | --- |
Regression: | --- | Mount Type: | --- |
Documentation: | --- | CRM: | |
Verified Versions: | Category: | --- | |
oVirt Team: | --- | RHEL 7.3 requirements from Atomic Host: | |
Cloudforms Team: | --- | Target Upstream Version: | |
Embargoed: | |||
Bug Depends On: | 953515 | ||
Bug Blocks: |
Description
Libor Miksik
2013-05-30 12:52:33 UTC
Since the problem described in this bug report should be resolved in a recent advisory, it has been closed with a resolution of ERRATA. For information on the advisory, and where to find the updated files, follow the link below. If the solution does not work for you, open a new bug report. http://rhn.redhat.com/errata/RHBA-2013-1018.html |