Description of problem:
I extended a domain from a lun which disappeared after the login and extend fails with the following unclear error:
Error while executing action Edit SAN Storage Domain configuration: Physical device initialization failed. Check that the device is empty. Please remove all files and partitions from the device.
Version-Release number of selected component (if applicable):
sf18
How reproducible:
100%
Steps to Reproduce:
1. in iscsi storage type with two hosts, create a domain from a lun on one server
2. in storage tab -> select the domain -> edit -> discover luns on a second storage server and log in to one lun
3. block connectivity to the lun from storage server2 and press OK on the edit domain dialogue
Actual results:
extend fails with the following error:
Error while executing action Edit SAN Storage Domain configuration: Physical device initialization failed. Check that the device is empty. Please remove all files and partitions from the device.
Expected results:
we need a clearer message for user.
also this part is not relevant:
Check that the device is empty. Please remove all files and partitions from the device.
Additional info: logs
Comment 3Kevin Alon Goldblatt
2014-10-26 09:49:49 UTC
Tested with V3.5 vt7
The error now reads "Error while executing action: Cannot extend Storage Domain. Storage device is unreachable from nott-vds2."
Moving to Verified!
Created attachment 761860 [details] logs Description of problem: I extended a domain from a lun which disappeared after the login and extend fails with the following unclear error: Error while executing action Edit SAN Storage Domain configuration: Physical device initialization failed. Check that the device is empty. Please remove all files and partitions from the device. Version-Release number of selected component (if applicable): sf18 How reproducible: 100% Steps to Reproduce: 1. in iscsi storage type with two hosts, create a domain from a lun on one server 2. in storage tab -> select the domain -> edit -> discover luns on a second storage server and log in to one lun 3. block connectivity to the lun from storage server2 and press OK on the edit domain dialogue Actual results: extend fails with the following error: Error while executing action Edit SAN Storage Domain configuration: Physical device initialization failed. Check that the device is empty. Please remove all files and partitions from the device. Expected results: we need a clearer message for user. also this part is not relevant: Check that the device is empty. Please remove all files and partitions from the device. Additional info: logs