Created attachment 828432 [details] upower -d Description of problem: upower uses wrong values for energy-full that are clearly above energy-full-design, thus miscalculating charge and triggering hibernation often. Version-Release number of selected component (if applicable): upower-0.9.20-1.fc19.x86_64 How reproducible: Steps to Reproduce: 1. boot f19 (rMBP in my case) 2. watch upower to go wrong (upower --monitor-detail) 3. Actual results: after some time (minutes, sometimes half an hour) the energy-full value becomes non-sensical high, percentage changes and hibernation follows. resume usually corrects this fro some time before the cycle starts again. Expected results: normal battery drain until empty then hibernation; energy-full shoudl never exceed energy-full-design. Additional info: see attachment(s)
Created attachment 828433 [details] grep -r . /sys/class/power_supply/BAT0
Created attachment 828439 [details] upower --montor-detail
I have the same problem with Fedora 20 for the past 2 months, bug 1060579 unfortunately noone has responded to my bug report either...
does anybody actually look at this bug?
with upower-0.9.23-3.fc20.x86_64 this issue never showed up again.