Note: This bug is displayed in read-only format because the product is no longer active in Red Hat Bugzilla.

Bug 1076928

Summary: [Docs] [Feature] DRAC7 now supported as a fence agent
Product: Red Hat Enterprise Virtualization Manager Reporter: Zac Dover <zdover>
Component: DocumentationAssignee: Lucy Bopf <lbopf>
Status: CLOSED CURRENTRELEASE QA Contact: Laura Novich <lnovich>
Severity: unspecified Docs Contact:
Priority: high    
Version: 3.4.0CC: gklein, jhradile, lbopf, lnovich, rbalakri, yeylon
Target Milestone: ---   
Target Release: ---   
Hardware: Unspecified   
OS: Unspecified   
Whiteboard:
Fixed In Version: Doc Type: Bug Fix
Doc Text:
Story Points: ---
Clone Of:
: 1090720 (view as bug list) Environment:
Last Closed: 2014-09-11 18:28:13 UTC Type: Bug
Regression: --- Mount Type: ---
Documentation: --- CRM:
Verified Versions: Category: ---
oVirt Team: --- RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: --- Target Upstream Version:
Embargoed:
Bug Depends On:    
Bug Blocks: 1090720    

Description Zac Dover 2014-03-16 15:32:54 UTC
As DRAC7 should be fully functional and supported with ipmilan fence agent, DRAC7 should be added to the fence agents list with ipmilan as implementation.

Steps to Reproduce:
1. Configure DRAC7 fence agent 

Actual results:
No DRAC 7 fence agent, implying this configuration is not tested and not supported. 

Expected results:
Existing DRAC7 fence agent in the supported fence agents list + in documentation
  --https://bugzilla.redhat.com/show_bug.cgi?id=1046625

Comment 1 Lucy Bopf 2014-04-17 02:00:18 UTC
'drac7' appears under Type in New/Edit Host -> Power Management tab.

Added drac7 to Power Management Settings table in Admin and Install Guides (10329).

Added drac7 to list of supported power management devices in Power Management section of Tech Guide (8956).

Comment 2 Lucy Bopf 2014-04-24 03:50:00 UTC
Documentation Link
------------------------------
http://documentation-devel.engineering.redhat.com/site/documentation/en-US/Red_Hat_Enterprise_Virtualization/3.4/html-single/Administration_Guide/index.html#sect-Explanation_of_Settings_and_Controls_in_the_New_Host_and_Edit_Host_Windows

What Changed
------------------------------
The following topic was revised to include drac7 as a power management device.

Host Power Management Settings Explained [ 10329-632194 ]

Updated revision history: [ 30102-632618 ]

NVR
------------------------------
Red_Hat_Enterprise_Virtualization-Administration_Guide-3.4-web-en-US-3.4-19.el6eng

Moving to ON_QA.

Comment 3 Lucy Bopf 2014-04-24 04:45:18 UTC
Edit

Should be:

NVR
------------------------------
Red_Hat_Enterprise_Virtualization-Administration_Guide-3.4-web-en-US-3.4-23.el6eng