Bug 1388906 - [DOCS] Disconnected instructions need atomic registry steps
Summary: [DOCS] Disconnected instructions need atomic registry steps
Keywords:
Status: CLOSED CURRENTRELEASE
Alias: None
Product: OpenShift Container Platform
Classification: Red Hat
Component: Documentation
Version: 3.3.1
Hardware: Unspecified
OS: Unspecified
low
low
Target Milestone: ---
: ---
Assignee: Ashley Hardin
QA Contact: Johnny Liu
Vikram Goyal
URL:
Whiteboard:
Depends On:
Blocks:
TreeView+ depends on / blocked
 
Reported: 2016-10-26 12:15 UTC by cmilsted
Modified: 2017-03-15 19:34 UTC (History)
5 users (show)

Fixed In Version:
Doc Type: If docs needed, set a value
Doc Text:
Clone Of:
Environment:
Last Closed: 2017-03-15 19:34:13 UTC
Target Upstream Version:


Attachments (Terms of Use)

Description cmilsted 2016-10-26 12:15:54 UTC
Document URL: 

https://docs.openshift.com/container-platform/3.3/install_config/install/disconnected_install.html

Section Number and Name: 

install and the disconnected install guide.

Describe the issue: 

We have a new scenario which is the Atomic Registry install:

deployment_subtype=registry

https://docs.openshift.com/container-platform/3.3/install_config/install/stand_alone_registry.html

The disconnected instructions need to be updated for this scenario as well. 

There is a new container which is the "openshift3/registry-console" container, this also is needed as I understand (this is the Cockpit web console) and the instructions for disconnected need to pull this container and cover how to install a stand-alone Atomic Registry in a disconnected manner.

My customer has no direct access to registry.access.redhat.com and relies on container images proxied via Satellite 6 to deploy disconnected. They need instructions for this.

Suggestions for improvement: 

Add a new section to the disconnected install entitled "installing the Atomic Registry disconnected"

Additional information:

Comment 3 Ashley Hardin 2017-02-23 21:50:38 UTC
Work in progress: https://github.com/openshift/openshift-docs/pull/3830

Comment 4 Johnny Liu 2017-03-06 10:10:20 UTC
Most of change are okay for me in the PR, only one place need be updated.

:latest-registry-console-tag: v3.4
should be updated to
:latest-registry-console-tag: 3.4


Because by default, registry-console installed by installer is using 3.4 as image tag without "v" prefix for tag.

Comment 5 Ashley Hardin 2017-03-06 20:15:29 UTC
Johnny, This is updated. Thank you!

Comment 6 Johnny Liu 2017-03-07 02:43:29 UTC
The PR looks good to me.

Comment 7 openshift-github-bot 2017-03-07 14:35:04 UTC
Commits pushed to master at https://github.com/openshift/openshift-docs

https://github.com/openshift/openshift-docs/commit/b9364b6b629c0a032d40ef022113cf93c7d0dc2c
Bug 1388906, Added information about disconnected installation of the Atomic Registry

https://github.com/openshift/openshift-docs/commit/4fdd88da9002a49355ad75e1691d5aedafc7f80c
Merge pull request #3830 from ahardin-rh/disconnected-atomic

Bug 1388906, Added information about disconnected installation of the Atomic Registry


Note You need to log in before you can comment on or make changes to this bug.