Hide Forgot
Created attachment 1220269 [details] screenshot Description of problem: fresh install a VM,and add two disks using virt-manager,create a raid 5 disk using cockpit web,you will see the error in journal and on the screen of the server system after you delete the raid. raid level 4 is the same. Version-Release number of selected component (if applicable): cockpit-123-1.fc25.x86_64.rpm How reproducible: always Steps to Reproduce: 1. 2. 3. Actual results: Expected results: Additional info:
Created attachment 1220270 [details] journal
RAID 4 and 5 require three disks to actually work, so with only two disks they usually fall back to RAID 1, hence the warning. What different behavior do you expect? Does using commandline storaged not throw a warning?
Sorry for the wrong input.I saw this when I was trying to reproduce a raid 1 bug,and I'm going to close the bug now.Maybe it's better to warn users when they try to create raid 5, raid 4 with two disks,like cockpit dose now for raid 6.