Bug 162188 - HWCERT: EVA 5000 / 3000
HWCERT: EVA 5000 / 3000
Status: CLOSED NOTABUG
Product: Bugzilla
Classification: Community
Component: Bugzilla General (Show other bugs)
1.0
x86_64 Linux
medium Severity medium (vote)
: ---
: ---
Assigned To: Red Hat Hardware Certification
Will Woods
http://h18006.www1.hp.com/products/st...
HP StorageWorks Enterprise Virtual Array
:
Depends On:
Blocks:
  Show dependency treegraph
 
Reported: 2005-06-30 13:56 EDT by Frank_Ehle
Modified: 2007-08-22 14:14 EDT (History)
0 users

See Also:
Fixed In Version:
Doc Type: Bug Fix
Doc Text:
Story Points: ---
Clone Of:
Environment:
Last Closed: 2005-07-21 16:19:55 EDT
Type: ---
Regression: ---
Mount Type: ---
Documentation: ---
CRM:
Verified Versions:
Category: ---
oVirt Team: ---
RHEL 7.3 requirements from Atomic Host:
Cloudforms Team: ---


Attachments (Terms of Use)

  None (edit)
Description Frank_Ehle 2005-06-30 13:56:08 EDT
Red Hat Hardware Certification Submitted

Product:        Red Hat Enterprise Linux
Version:        4
Make:           ProLiant
Model:          DL585 G1
Vendor:         Hewlett Packard
Category:       Component/Peripheral
Reporter:       ehle@hp.com
Kernel Version: kernel-smp-2.6.9-11.EL

File Uploaded:
rhr2-ProLiant-DL585_G1-Nahant_Update_1_results-1.noarch.rpm
https://bugzilla.redhat.com/hwcert/data/rpms/b0f6fc5f7454af791bae49655c9d5c4a/rhr2-ProLiant-DL585_G1-Nahant_Update_1_results-1.noarch.rpm

0   FAILED   INFO
    PASSED   STORAGE
Comment 1 Chris Williams 2005-07-14 15:21:33 EDT
Frank,
What devices were tested?

In dmesg I see MSA100, EVA, EVA_XL and XP.

In the hardware.log for the STOARGE test I see MSA100, HSV210, HSV110. 

How do these correlate to EVA 5000/3000?
Comment 2 Frank_Ehle 2005-07-14 17:14:53 EDT
Representation for all HP SAN arrays were present for testing. 
The HSV110 is the representative controller for the EVA 5000/3000.
The HSV210 is EVA 4000/6000/8000.
The OPEN* devices represent the XP512/48, XP128/1024, and XP120000.
Then finally there is the MSA family of arrays (differing firmware) - MSA1000 
with the 4.32 firmware and the MSA1500 with the 4.94 firmware.