HTS does not identify that storage tests are needed for an HP585DL G1, with RAID via ccis.
Fixed storage test to be planned if a cciss PCI device is found. The test does not run correctly for RAID - See RHR2 test.
The problem is storage test doesn't find this "cciss" device, fixed it now. Please see the following details: ------------------------------------------- <17:29:51 kun@yangkun>$ diff -uNr storage.sh.orig storage.sh --- storage.sh.orig 2006-11-02 17:28:35.000000000 +0800 +++ storage.sh 2006-11-02 17:29:51.000000000 +0800 @@ -135,7 +135,9 @@ # find the storage devices -YangKun get_storage_info() { - hal-device | fgrep block.device | awk '{print $3}' | tr -d "'"[0-9] | colrm 1 5 | sort -u + # use another way to find storgae info # YK + /sbin/fdisk -l | grep Disk | awk '{print $2}' | tr -d ":" | colrm 1 5 | sort -u +# hal-device | fgrep block.device | awk '{print $3}' | tr -d "'"[0-9] | colrm 1 5 | sort -u } STORAGE_DEVICES=`get_storage_info` @@ -262,7 +264,7 @@ if [ "$testdev" == "$swapdev" ]; then restore_swap $swapdev; fi # remove temp directories -YangKun - rmdir $device.* + #rmdir $device.* 2>/dev/null fi done <17:29:56 kun@yangkun>$