Bug 2211608 - LSM causes discrepancy "Image UUID has a different attribute type on storage(SPARSE) and on DB(PREALLOCATED)"
Summary: LSM causes discrepancy "Image UUID has a different attribute type on storag...
Keywords:
Status: CLOSED NEXTRELEASE
Alias: None
Product: Red Hat Enterprise Virtualization Manager
Classification: Red Hat
Component: ovirt-engine
Version: 4.5.3
Hardware: Unspecified
OS: Unspecified
high
medium
Target Milestone: ovirt-4.5.3-async
: ---
Assignee: Arik
QA Contact: Shir Fishbain
URL:
Whiteboard:
Depends On:
Blocks:
TreeView+ depends on / blocked
 
Reported: 2023-06-01 08:30 UTC by Marian Jankular
Modified: 2023-08-03 11:00 UTC (History)
7 users (show)

Fixed In Version:
Doc Type: Bug Fix
Doc Text:
If this bug requires documentation, please select an appropriate Doc Type value.
Clone Of:
Environment:
Last Closed: 2023-08-03 11:00:24 UTC
oVirt Team: ---
Target Upstream Version:
Embargoed:


Attachments (Terms of Use)


Links
System ID Private Priority Status Summary Last Updated
Github oVirt ovirt-engine pull 875 0 None open Do not change qcow+preallocated volumes when moving disks 2023-07-18 20:05:44 UTC
Github oVirt ovirt-engine pull 876 0 None open core: do not change qcow+preallocated volumes when moving disks 2023-07-25 08:57:54 UTC
Red Hat Knowledge Base (Solution) 7022817 0 None None None 2023-07-03 11:21:13 UTC

Description Marian Jankular 2023-06-01 08:30:30 UTC
Description of problem:
when moving a block-based preallocated disk with incremental backup enabled (format: COW, type: PREALLOCATED) to another block-based SD it is moved as (format: COW, type: SPARSE)

Version-Release number of selected component (if applicable):
vdsm-4.50.3.7-1.el8ev.x86_64

How reproducible:
every time

Steps to Reproduce:
1. move block-based preallocated disk with incremental backup enabled (format: COW, type: PREALLOCATED) to another block-based SD

Actual results:
image is - format: COW, type: SPARSE

Expected results:
the image will be - format: COW, type: PREALLOCATED

Additional info:

Comment 6 Arik 2023-07-17 09:17:26 UTC
Benny, you said it sounds familiar, can you please take a quick look?

Comment 7 Casper (RHV QE bot) 2023-07-18 20:30:25 UTC
This bug has low overall severity and is not going to be further verified by QE.

Comment 8 Arik 2023-07-23 06:20:38 UTC
verification steps:
1. create a VM with a disk that is set with incremental-backup enabled a on storage domain
2. start the VM (not mandatory I think but that's part of the reported issue)
3. verify the disk configuration is qcow+preallocated with (on the host that the VM runs on): vdsm-tool dump-volume-chains <storage domain id> | grep -A3 <image id>
4. move the disk to another block storage domain
5. when the disk movement completes, verify the disk configuration remains qcow+preallocated with the aforementioned command in step 3 (that points to the new storage domain)

Comment 11 Casper (RHV QE bot) 2023-08-03 11:00:24 UTC
This bug has low overall severity and passed an automated regression suite, and is not going to be further verified by QE.